Thanks to Jon Caldwell, U.S. Department of Veterans Affairs, USA.
Thanks to Mike Hampton, First Nationwide Bank, USA.
Change 13.285 Cosmetic documentation change. References to ANALDB2 were
ADOCDB2 changed to DIFFDB2, the "four datasets" note was changed
DIFFDB2 to "three datasets", and change 12.033 is referenced
Dec 12, 1995 instead of change 12.034.
Thanks to Nico Lenaerts, SAS BELGIUM, BELGIUM.
Change 13.284 REXX program to convert GTF trace records from DB2 into a
REXXDB2 legitimate (un-segmented) records had typographic errors.
Dec 12, 1995 -All C2K should have been C2X instead.
-The NE should have been <> instead.
-The statement I=REC must be changed to F=REC.
-The concatenation symbol '6A'x needs to be '4F'x for MVS.
That character is mis-translated between EBCDIC/ASCII by
many upload/download packages, so the actual change was
to replace F=F||G with F=(F)(G)so that the
REXX program is impervious to upload/download.
Thanks to Eric Thornton, D&B, USA.
Thanks to Chuck Hopf, MBNA, USA.
======= Attended CMG 95 Conference in Nashville, Tennessee ============
Change 13.283 Support for TANDEM D20, D30, and D40 releases is added
VMACTAND compatibly. However, I found I cannot trust the TANDEM
Dec 2, 1995 MEASURE documentation; its DLLs show changes where there
Dec 12, 1995 were none! (Fortunately, CMG came to the rescue as there
Jan 3, 1996 I met a TANDEM employee who put me in touch with the real
programmer who wrote the code!). Two variables were added
compatibly by D30 (BEGTRANS,ABRTRANS) by using reserved
space in the PROCESS record. Several measurement fields
(lock-pages-qtime/count and UCL-lock-qtime/count in the
PROCESS record, and the four pairs of START/END variables
for UDS-LOCK, SDS-LOCK,UCL- LOCK, and SCL-LOCK in the
DISC record) were made reserved fields in D40 (because
they were too expensive to capture!). The DDL for D40 are
wrong, as they show BEGTRANS/ABRTRANS in the wrong place,
and the now-reserved fields were deleted from the DDL,
but they were not deleted from the physical record.
Thanks to Joe Fleischmann, US Bancorp, USA.
Thanks to Todd Tomita, US Bancorp, USA.
Thanks to Steve Smith, BGS Systems, USA.
Change 13.282 MAINTLEV 7 of the MXG Tape Mount and Allocation Monitor
ASMTAPES corrects the JSCB access problem, the CA-11 restart case,
Nov 30, 1995 and supresses the SRB dump messages (unless we ask you to
enable DEBUGGING!). This iteration has been running in
two sites for several weeks with no failure. The previous
monitor code was copied into ZSMTAPES for backup.
Change 13.281 This replacement for member CICINTRV is temporarily put
CICINTRZ in this member for extensive testing, but it will become
Nov 30, 1995 CICINTRV in the near future. The present CICINTRV logic
is incorrect, and this new logic correctly creates the
CICS interval datasets from the statistics datasets.
This version first summarizes the individual datasets at
the lowest level, and performs deaccumulation with DIF()
function for the REQ and USS records so that all four
types of CICS stat records are correctly summarized into
the CICINTRV dataset. Note that this can be resource
intensive if you have lots of CICS activity, but you can
construct the CICS activity from these statistics records
even if you have turned off CICSTRAN creation!
Revised Jun 13, 1996: Resources are not a problem; see
resource measurements in text of Change 14.132, which
implemented these enhancements starting with MXG 14.04.
Thanks to Chuck Hopf, MBNA, USA.
Change 13.280 Correction. If no summary dataset was created, but
ANALCNCR summary reports were requested, the summary reports were
Nov 30, 1995 not produced.
Change 13.279 New parameters SMFBEGIN and SMFEND were added to allow
READDB2 selection while the raw SMF records are read. These new
Nov 30, 1995 parameters are now used by ANALDB2R (Change 13.278).
Change 13.278 Several enhancements to DB2 reporting.
ANALDB2R -Reports can now be produced from MNTHxxxx datasets, if
Nov 30, 1995 you have used the MNTHxxxx members to trend monthly.
-When reading SMF, the BEGTIME and ENDTIME values are now
passed to READDB2 (as SMFBEGIN/SMFEND) so that selection
applies to the raw data as it is read, which will reduce
DASD space and run time, especially with big traces.
Change 13.277 This utility (used only in JCLTEST6, to select ten SMF
VMXGGETM records of each type) has new INCODE= operand added to
Nov 30, 1995 enhance selection criteria, for those of you who have
found this utility useful! You could now code
INCODE=IF (ID=30 AND 4 LE SUBTYPE LE 5) OR ID=72; ,
to select only those records and subtypes.
Thanks to Chuck Hopf, MBNA, USA.
Change 13.276 The revised VMXGSUM logic has been moved from XMXGSUM to
VMXGSUM VMXGSUM, and member XMXGSUM has been deleted. (Just in
XMXGSUM case, the old VMXGSUM was copied into ZMXGSUM for backup,
ZMXGSUM but that member too will go away in time). The new logic
Nov 30, 1995 in VMXGSUM will significantly reduce the DASD space, CPU
time and run time, as it keeps only the variables that
are actually needed by the summarization, and (unlike the
old VMXGSUM), it does not create dummy variables in
the output dataset. It also supports variable lists with
hyphenated syntax. Many sites with large data volumes
have been using the XMXGSUM logic, so I believe it is now
safe to make the MXG default to be the new logic.
Change 13.275 New parameters INTERVAL and MYTIME are defined for report
ANALRMFR summarization, but they are only implemented in MXGCHAN
Nov 30, 1995 report at this time.
Change 13.274 CICS shutdown reports CICCONSR or CICCONMR can cause many
ANALCISH blank pages with only the heading and no content; several
Nov 30, 1995 line changes were required, too complicated to show here.
Also, END; statement was missing after IF INOBS EQ CXMC.
Thanks to Richard S. Ralston, Whirlpool. USA.
Change 13.273 Support for DB2 4.1 type 102 trace records has tested the
VMAC102 new IFCIDs 221, 222, and 231 for parallel group tracing,
Nov 30, 1995 and adds new fields in existing trace datasets for IFCIDs
8, 10, 20, 21, 22, and 28. There are still other fields
added to other IFCIDs by 4.1 that are not yet decoded by
MXG due to absence of test data records; those will be
added when user demand and test data arrive together.
Thanks to Ted Blank, IBM, USA.
Change 13.272 Corrections to several variables in HP PCS records:
VMACHPAI -VMACHPUX, comment now has HPUX as correct INFILE name.
VMACHPSU -VMACHPUX, PIN variable removed from LENGTH statement so
VMACHPUX that it will be numeric rather than character (as it was
Nov 29, 1995 in HPAI and HPSU members, like all other PINs).
-INTEREST now input as INTEREST $CHAR12. (instead of with
no INFORMAT) as the file may contain leading blanks.
First test for INTEREST that sets IMPWTHI was deleted.
Last four tests for INTEREST must test for lower case
letters c,d,m,i rather than upper case values.
Thanks to Thierry Van Moer, Procter & Gamble Europe, Belgium.
Change 13.271 Variables SYSNAME and SYSPLEX were not kept in BUILDPDB
IMACPDB datasets PDB.JOBS, PDB.STEPS, and PDB.PRINT, but they are
Nov 29, 1995 now added to _PDB30_1, _PDB30_4, and _PDB30_5 macros in
member IMACPDB so they will be kept in the PDB datasets.
Thanks to Dr. Alexander Raeder, Karstadt AG, GERMANY.
Thanks to Harmuth Beckmann, Karstadt, AG, Germany
Change 13.270 IBM writes truncated EREP records, but MXG did not catch
VMACEREP the truncation, causing INPUT STATEMENT EXCEEDED RECORD
Nov 29, 1995 for a hardware detected VLF software record. Protection
was added for dataset EREPSDW. Additionally, the ERRORID
field at the end of the SDW record was not input from the
correct location, and variable CLASRC is now kept in the
EREPSDW, EREPEOD, EREPMDR, and EREPOBL datasets.
Thanks to Solomon Baker, The Prudential Service Company, USA.
Change 13.269 Variables QBSTHPL and QBSTVPL were removed from DIF()'ing
DIFFDB2 because they are not accumulated values, but rather are
Nov 28, 1995 the number of hiperspace and virtual pool buffers.
Thanks to Alan Fendler, Pershing Info Management Services, USA.
Change 13.268 Variable USER was added to the default summarization of
ASUMCICS CICSTRAN dataset into PDB.CICS, because OPERATOR is now
Nov 28, 1995 usually blank, while USER contains the wanted user-id.
Dec 18, 1995 The summarization default is now by
APPLID OPERATOR USER TERMINAL TRANSACT (for each hour).
Thanks to Clark Jennings, Reynolds Metal, USA.
Change 13.267 Another IDMS 12.01 error, INVALID DATA FOR PMHSDATE for
VMACIDMS the PMHRTYPE=6 (Journal Wait) subtype. The statement
Nov 20, 1995 SKIP=SKIP-108; that is two lines prior to the statement
%%INCLUDE SOURCLIB(EXIDMJRL); should been
SKIP=SKIP-104;. (My test data stream did not have any
journal wait data, but this was an MXG coding error.)
Thanks to Dan Gilbert, Bergen Brunswig Corporation, USA.
Change 13.266 Variable STARTIME was missing TSOMCMND if the TSO/MON
VMACTSOM SMF record was written in segments (because there were
Nov 20, 1995 more logged on users that would fit in one SMF record).
STARTIME was added by Change 13.089 for consistency, but
the pre-existing, same value variable STRTTIME was never
wrong! Immediately following STRTTIME=TSOMSTAR; insert
STARTIME=STRTTIME;
Thanks to Neil Ervin, Huntington Services Co, USA.
Change 13.265 Support for IMS 5.1 records (INCOMPATIBLE) was reported
ASMIMSLG with these changes.
VMACIMS -ASMIMSLG - Replace these three non-contiguous lines
Nov 17, 1995 TM MSGCFLG1,MSGC1RAC TM MSGCFLG1,MSG3RACF
---17 lines ----
USING MSGRACF,R4 USING MSGSEC,R4
--- 8 lines ----
MVC ORGENT(8),MSGRACGP MVC ORGENT(8),MSGSAFNM
(with this change to ASMIMSLG, it can ONLY process 5.1
records, so you will need to maintain two separate load
libraries and separate job streams).
VMACIMS
18 new 4-byte fields were inserted in the 07 log record
between MSGGCMD and PDATE.
This is a documentation only change at this time, as I am
still awaiting data and documentation so that I can
validate this report and then change the MXG coding.
Now, see Change 14.030.
Thanks to Mr. Hellmann, Sudwestdeutsch Landesbank, GERMANY.
Change 13.264 TANDEM disk type format MGTANDS values are decimal, not
VMACTAND hex, so the "X"'s were removed, and the 35:3GB value has
Nov 16, 1995 replaced the 35:MGB spelling.
Thanks to Steve Smith, BGS Systems, USA.
Change 13.263 IBM lied, and JESNR may show only four digits in TYPE26J2
VMAC26J2 dataset (and if BUILDPDB finds only a purge record for a
Nov 13, 1995 job, its PDB.JOBS observation will have JESNR=1179 where
Feb 26, 1996 it should be JESNR=11179. IBM documentation of SMF26JNM
(the old, 4-position EBCDIC JESNR) says it will be zero
if the job number is 10,000 or greater, causing MXG to
get JESNR from SMF26JID, and this was true until now, but
it appears MVS/ESA 5.2 with JES x.y are now putting the
truncated JESNR back into SMF26JNM! While I chase after
the IBM INCOMPATIBLE change to type 26 record, I can fix
the MXG logic to work no matter what IBM does. Change:
ELSE DO;
IF JESNR GT 0 THEN
INPUT @57+OFFSMF TYPETASK $EBCDIC3.
+5
@;
ELSE
INPUT @57+OFFSMF TYPETASK $EBCDIC3.
@60+OFFSMF JESNR &NUM.5.
to read:
ELSE DO;
INPUT @57+OFFSMF TYPETASK $EBCDIC3.
@60+OFFSMF JESNR &NUM.5.
Feb 26, 1996 update: IBM APAR OW18822 acknowledges the
error and should correct the non-zero value back to zero,
but the MXG correction in MXG 13.13 fixes it anyhow!
Thanks to Tim Terbieten, Newell Company, USA.
Change 13.262 Variable DEVPLX, the device address of the duplex volume,
VMACACHE is an offset from the first device instead of the real
Nov 8, 1995 device number; now, DEVPLX will contain the true device
Dec 2, 1995 number by inserting these lines:
IF NDVCNT=1 THEN BASDEVN=DEVN;
IF DEVS1='....1...'B THEN DEVPLX=BASDEVN+MOD(DEVS2,64);
before the %%INCLUDE SOURCLIB(EXCAC90); statement.
I note that the Cache record does not contain a segment
for the duplex device; DEVPLX=05x, BASDEVN=2C0x, so the
duplex device address is now DEVPLX=2C5x, but there will
be no observation in CACHE90 with DEVN=2C5x.
The above correction worked until MVS/ESA 5.2, which has
caused an unexpected (at least by the CRR-folks) change
in the CRR record. The BASE device number used to be the
first device segment returned by the 3990 controller, and
that address is copied into the statistics segment. But
in 5.2, the order in which devices are varied online at
IPL is different, and the 3990 returns devices in order
they came online, so the base device is no longer going
to be in the first segment. IBM CRR Level II has this;
when they decide what they are going to do, so will I!
Thanks to Kurt Koch, West Publishing Corporation, USA.
Change 13.261 SAP Journal segments in type 110 records caused error
VMAC110 INPUT STATEMENT EXCEEDED, or INVALID DATA FOR HH, or did
Nov 8, 1995 not read in all segments in the SMF record, because MXG
Jan 13, 1996 did not anticipate that SAP would create journal segments
with only a header,
(found for the YISA APPC host-to-host connection
application, with JCSPTRAN='YISA', JCRLL=30, so there
is no data - these segments may be output into a new
dataset if there is usefulness, and this fix still
leaves them available in the EXCICJRN exit),
or with JCRUTRID not containing 'SA',
(found for a most strange segment between other 'SA's,
containing a Global Performance Interval segment with
MCTSSDID=2 which belongs in a subtype =1 record and
is normally output into CICSYSTM from that subtype!;
UPDATED Jan 13. SAP Technical Support has not responded,
but the second problem is circumvented in Change 13.323.
Header only segments are skipped over with these changes:
-Delete the line ... INPUT +6 SAPTEST $EBCDIC2 @LOC @;
-Change IF SUBTYPE=0 OR SAPTEST='SA' THEN DO UNTIL ...
to IF SUBTYPE=0 THEN DO UNTIL ...
-Change IF JCRUTRID='SA' THEN DO;
to IF JCRUTRID='SA' AND JCRLL GE 250 THEN DO;
Unrelated to the above errors, variable APPLID was added
to the KEEP= list for the CICSSAP dataset so CICSSAP can
be analyzed for each CICS region.
Thanks to Jens Schlatter, EDP Consulting Schlatter, GERMANY.
Thanks to Norbert Korsche, OMV, AUSTRIA.
Thanks to Paolo Carloni, Agip petroli SPA, ITALY.
Thanks to ????, Deutsche Post AG, GERMANY.
Change 13.260 RMDS 1.4 records may cause INVALID ARGUMENT TO MDY AT ...
VMACRMDS because only some MDY() functions were protected for the
Nov 8, 1995 'strange' values MO=99 and DD=99.
Feb 26, 1996 -Now, all uses of MDY() are protected with logic of the
form:
IF YY GT 0 AND (YY NE 99 AND MO NE 99 AND DD NE 99)
THEN xxxxDATE=MDY(MO,DD,YY);
-In addition, INVALID DATA FOR MM can occur, because only
some INPUTs of HH MM and SS were protected with the ??
modifier. Now, all fields input with &NUM are preceded
by the double-question-mark modifier.
-Finally, all HMS() functions are now protected with
IF 0 LE HH LE 24 and 0 LE MM LE 60 and 0 LE SS LE 60
logic to prevent invalid arguments to HMS() function.
-The error does not occur with current RMDS 2.1 or later.
Note added Feb 26, 1996: The support for RMDS 1.3/1.4
also deleted the two tests:
IF RMDSACT='D' and RMDSORG NE 'A' THEN RMDSACT='T';
IF RMDSACT='U' AND RMDSORG EQ 'V' THEN RMDSACT='S';
because the activity codes of 'T' and 'S' do not exist
in RMDS version 2.1.
Thanks to Ambat Ravi Nair, Trident Infotech Pte Ltd, SINGAPORE.
Change 13.259 MXG 13.06-13.07 only. ABARS enhancement validation:
EXHSMWWV -UNEXPECTED IDHMSMDS RECORD FOUND because the line now
IMACHSM reading ELSE IF DSRVSR='VRS' THEN ... should have been
VMACHSM ELSE IF DSRVSR='VSR' THEN ....
Nov 8, 1995 -INPUT STATEMENT EXCEEDED RECORD LENGTH on ABARS subtype
Nov 15, 1995 because the four fields WFSRML0U,WFSRML1U,WFSRML2U, and
WFSRTOTU at the end of both ABARS segments are now INPUT
as $EBCDIC1. instead of &PIB.4. MXG now decodes the unit
of space value (blank, K, M, etc.) and converts the space
used during ABACKUP variables WFSRML0S,L1S,L2S,TOTS into
bytes, and are formatted with MGBYTES to print pretty.
-Variable WFSRABCC is now input as $EBCDIC4. vice &PIB.4.
-IBM clarified several issues. Space units of K,M,G,T are
1024 (as expected, but since IBM used 1000 for hardware
"K", and since the ABARs documentation did not say, we
had to ask!). Also, ABACKUP VERIFY does cut a shorter
record that does not contain the space information fields
while ARECOVER creates a longer record, but zeroes out
the space information fields.
-New HSM dataset HSMWWVOL is created, but with zero obs
until you remove the comment block in member EXHSMWWV.
(This dataset will contain one obs for each volser that
was used by ABARS for backup, and I perceive little need
for that information; the useful ABARS information is in
the HSMWWFSR dataset, one obs per ABARS event.)
Thanks to Michael E. Friske, Fidelity Savings, USA.
Change 13.258 Very obscure, and only for the early users of XMXGSUM.
XMXGSUM Change the second occurrence of NUMPOS= from &HYPHEN1 to
Nov 6, 1995 &HYPHEN2. Would have caused an OUT OF MEMORY error.
Change 13.257 Variable AVGQUETM should not have been in the keep list
VMAC7072 for dataset TYPE72GO, as that field is from the subtype 2
Nov 6, 1995 (RMF Monitor III) record, and is output only in TYPE72MN.
Thanks to Don Deese, (CPExpert), Computer Management Sciences, USA.
Change 13.256 Variable QBGAGN should be kept only in DB2ACCTG, and not
VMACDB2 in DB2ACCT, and it should not have been summed during the
Nov 6, 1995 creation of DB2ACCTG. It is the pool ID, not a counter!
Thanks to Chuck Hopf, MBNA, USA.
Change 13.255 Tandem variables CnMISSES was repeated in INPUT; the two
FORMATS instances are now named CnRMISS and CnWMISS for Read or
VMACTAND Write misses. C1BLKS is no longer divided by DURATM, as
Nov 6, 1995 it is blocks allocated, not blocks moved in interval.
Format MGTANDS was updated with device 1Fx and will now
print un-coded values in hex rather than decimal.
Thanks to Steve Smith, BGS Systems, USA.
Change 13.254 Support for TOPSECRET Release 4.4 and 5.0, INCOMPATIBLE,
VMAC80 CAUSES INPUT STATEMENT EXCEEDED RECORD error, because the
VMAC80A new release sets a value of 44X or 50X for RACFVRSN, but
Oct 31, 1995 MXG does not know in advance what value TOPSECRET will
use! Add OR RACFVRSN=44X OR RACFVRSN=50X to the test
for TOPSECRET in both members. (44X exists in 4.4 data;
5.0 is not out yet, so I am gambling in advance that they
will use 50X for that version when it's released!).
Thanks to Mark Paulson, Maurices Incorporated, USA.
Thanks to Sarah Gartner, Hudson's Bay Company, CANADA.
==========MXG Version 13.07, dated Oct 30, 1995, thru 13.253==========
Change 13.253 SAP 5.0.E creates invalid journal segments, which caused
VMAC110 INVALID DATA FOR HH and a hex dump of the record, but MXG
Oct 27, 1995 successfully skipped over the invalid segments and output
the valid ones. SAP had no one in tech support on Friday
to discuss their error before MXG 13.07 was built, but I
will pursue this with them later and update this note.
To eliminate the hex dump and message, insert ?? after
HH and MM following the INPUT of JCSPTASK.
Update: See Change 13.323.
Thanks to Paolo Carloni, Agip petroli SPA, ITALY.
Change 13.252 $AVERS SMF record variables SAVPAGES,SAVBLKS,SAVTBLKS are
VMACSAVR now created; these fields existed at the end of the SMF
Oct 27, 1995 record, but were not populated until this user went to
use them! The vendor, Software Engineering of America,
will fix the error in SAVRS V4.0A.33, and interim fix
number S40AF166 (a ZAP) is available from them now that
will populate these fields.
Thanks to Bill Hamilton, Scottish Widows, SCOTLAND.
Change 13.251 Support for STK's SILO SMF HSC View Subtype 8 record now
EXSTCHSV creates dataset STCHSV for every successful VIEW command
IMACSTC initiated by HSC.
VMACSTC
Oct 26, 1995
Thanks to Cheryl Howard, Wachovia Corporation, USA.
Thanks to Rodney L. Reisch, Wachovia Corporation, USA.
Change 13.250 DURATM was added to TSO/MON datasets by Change 13.089,
VMACTSOM but it was often missing! After the second statement
Oct 26, 1995 INTRVTM=TSOMDUR; insert DURATM=INTRVTM;
Thanks to Dan Squillace, SAS Institute Cary, USA.
Change 13.249 Support for MODEL204 Release 3.0 INCOMPATIBLY added five
IMACM204 fields to the SINCE record. Since there is no release
VMACM204 number in their record, you MUST update member IMACM204
Oct 25, 1995 in your USERID.SOURCLIB to use this new IMACM204, as it
now also defines macro _M204VER which tells MXG to read
Release 2 or Release 3 records (default is for Rel 3).
Thanks to Mark Wessel, Population Census & Surveys Office, ENGLAND.
Change 13.248 Summarization of IDMSTAS dataset from IDMS Perfmon into
ASUMIDMS PDB.ASUMIDS is provided by this user contribution, which
Oct 25, 1995 mimic's ASUMCICS algorithms to create response time and
resources by CV_NUM DC_USER DC_LTERM TASKCODE ADSODLGN.
Thanks to Richard S. Ralston, Whirlpool, USA.
Change 13.247 CICS/ESA 4.1 or later now contains the GMT offset, so MXG
VMAC110 can finally convert the STRTTIME/ENDTIME in CICSTRAN to
Oct 25, 1995 your local time of day. The INPUT of MCTMNTAD is changed
from &PIB.4. to &IB.4., and this line inserted:
MCTMNTAD=1.0485582324*MCTMNTAD;
to convert from CICS timer units to seconds. Then, in
the CICS/ESA 4.1 section for CICSTRAN and CICSEXCE, the
logic IF MCTMNTAD GT . THEN DO;
STRTTIME=STRTTIME+MCTMNTAD;
ENDTIME =ENDTIME +MCTMNTAD; END;