The logical AND results in more restrictive

filtering because 2 conditions must be met for an

OPD entry to be selected.
Example 2 with OPDOR in effect:

OPDJOBNAME=ABC* OPDUSERNAME=SAM*

selects Address Spaces in the RMF Monitor III OPD table

that have a Job Name starting with 'ABC' OR a User Name

beginning with 'SAM'.

If the Address Space does not match either selection it

is filtered and will not appear in the result MXG PDB.

The logical OR results in less restrictive filtering than

Example 1 above because any of the 2 conditions results

in data selection of an OPD entry.

-The JOBNAME= (alias JOB=) keyword for multi-table

selection is expanded to include job names from the OPD

table as well as the ASI and CSR tables. This is a

convenience feature to avoid having to code the Job Name

parameter three times when the same job names from all

three tables are of interest.

-The ASI, CSR, and OPD tables must all be selected for the

JOBNAME= multi-table selection keyword to function

completely. Otherwise only entries from selected tables

are filtered.

Note that most RMF III tables do not contain common

character data fields, but in this case the ASI, CSR, and

OPD tables all do contain a Job Name.

JOBNAME= Examples:

JOBNAME=ABC88888 selects only address spaces with a Job

Name of 'ABC88888' in either ASI, CSR, or OPD tables and

is equivalent to coding:

ASIJOBNAME=ABC88888

CSRJOBNAME=ABC88888

OPDJOBNAME=ABC88888

JOBNAME=ABC:ABC88888 selects only address spaces with a

Job Name that is GE 'ABC' and LE 'ABC88888' in either

ASI, CSR, or OPD tables and is equivalent to coding:

ASIJOBNAME=ABC:ABC88888

CSRJOBNAME=ABC:ABC88888

OPDJOBNAME=ABC:ABC88888

JOBNAME=.* selects only address spaces with a Job Name

that begins with a national character in either ASI, CSR,

or OPD tables and id equivalent to coding:

CSRJOBNAME=.*

OPDJOBNAME=.*

-Some RMFV001I Execution Environment messages have been

reformatted to include DFSMS/MVS version, CPC Name, LPAR

Name (if not a VM Guest), or VM Userid (if a VM Guest).

TIOT statistics are now grouped on the same message line.

-The Creation date was not valid when non-VSAM data set

was incorrectly provided as a RMF III data set. CRDATE

is removed from the RMFV008I message in this case.

-The MXG00 record version is raised to x'07' from x'06'.

New fields added to the MXG00 record are:

IPL timestamp in LOCAL and GMT time

IPL volume serial

TIOT size in K and bytes

TIOT maximum and used entries

CPC Name, LPAR Name, and VM UserId

DFSMS/MVS level

-Several documentation Sections are updated to support

the above changes:

Section 5 "Input Data Selection Parameters"

Section 12 "Messages"

Section 13 "Filtered Records"

Section 25 "Ranges and Patterns"

Section 30 "Summary"

-VMACRMFV was updated to add new variables to ZRBASM:

ASMDFLVL='EXECUTION*DFSMS/MVS*LEVEL'

ASMOPNRX='MAXIMUM*OPDPROCNAME*RANGES'

ASMOPNPX='MAXIMUM*OPDPROCNAME*PATTERNS'

ASMOJNRX='MAXIMUM*OPDJOBNAME*RANGES'

ASMOJNPX='MAXIMUM*OPDJOBNAME*PATTERNS'

ASMOUNRX='MAXIMUM*OPDUSERNAME*RANGES'

ASMOUNPX='MAXIMUM*OPDUSERNAME*PATTERNS'

ASMOJNRS='SIZE*OPDJOBNAME*RANGE*TABLE'

ASMOJNPS='SIZE*OPDJOBNAME*PATTERN*TABLE'

ASMOPNRS='SIZE*OPDPROCNAME*RANGE*TABLE'

ASMOPNPS='SIZE*OPDPROCNAME*PATTERN*TABLE'

ASMSPGAO='SPG*MULTI*FILTER*LOGIC*I/O?'

ASMSINDD='SYSIN/SYSINA*DCB*DDNAME'

ASMVFREE='FREE=CLOSE*OPTION?'

ASMSINMG='SYSIN*MEMBER*OR*GENERATION'

ASMOUNRS='SIZE*OPDUSERNAME*RANGE*TABLE'

ASMOUNPS='SIZE*OPDUSERNAME*PATTERN*TABLE'

ASMIPLTL='LAST IPL*LOCAL*TIME'

ASMIPLTG='LAST IPL*GMT*TIME'

ASMTIOTB='MAXIMUM*TIOT SIZE*BYTES'

ASMTIOTK='MAXIMUM*TIOT SIZE*IN K'

ASMTIOTX='MAXIMUM*TIOT*ENTRIES'

ASMTIOTU='CURRENT*TIOT*ENTRIES*IN USE'

ASMCPCNM='CPC*NAME'

ASMLPARN='LPAR*NAME'

ASMVMUID='VM*USERID'

ASMIPLVL='IPL*VOLUME*SERIAL*NUMBER'
Change 35.053 SYSOTHER checking is enhanced. Test for CPUTM NE 0 added

VMXGRMFI to SYSOTHER detection, since if the CPUTM is 0 it cannot

Feb 28, 2017 impact totals, but workload names and descriptions are

identified so you can find the culprit, since nothing

should ever fall thru to Service Class SYSOTHER.
Change 35.052 DATETIME syntax was revised per change 35.022, although

TRNDVMXA the new VMXGSUM correctly supported the old syntax with

Feb 28, 2017 no error.
Change 35.051 Support for Liberty 17.0.0.1 SMF 120 Subtype 12 COMPAT

VMAC120 enhancements, adds these variables to TYP12012 dataset:

Feb 28, 2017 SM120CDO='REFERENCE*TYPE' MG120CD format decodes:

1='1:READER'

2='2:PROCESSOR'

3='3:WRITER'

4='4:CHECKPOINT'

5='5:BATCHLET'

6='6:PARTITION_MAPPER'

7='7:PARTITION_REDUCER'

8='8:PARTITION_COLLECTOR'

9='9:PARTITION_ANALYZER'

10='10:DECIDER'

SM120CDU='PHYSICAL*CPU*ADJUSTMENT*RCTPCPUA'

SM120SU_SEC='CPU*RATE*ADJUSTMENT*RMCTADJC'

SM120CDW='REPOSITORY*TYPE*JPA* OR MEM'

SM120CDX='JOB*STORE*REF*ID'

SM120CDY='SM120CDY*FLAGS'

Next six variables are only valid in step end record

SM120CDZ='STEP*START*LIMIT'

SM120CEA='CHUNK*STEP*CHECKPOINT*POLICY' decodes:

0='0:ITEM'

1='1:CUSTOM'

SM120CEB='CHUNK*STEP*ITEM*COUNT'

SM120CEC='CHUNK*STEP*TIME*LIMIT'

SM120CED='CHUNK*STEP*SKIP*LIMIT'

SM120CEE='CHUNK*STEP*RETRY*LIMIT'
Change 35.050 PDB.ASUMCELP REQUIRES SMF 70s from ALL SYSTEMs to be read

VMXG70PR to correctly populate all variables. Each SMF 70 record

Feb 27, 2017 contains a "This System" segment that populates TYPE70,

and an "LPAR Segment" for each LPAR, for TYPE70PR, so the

LPAR data can be reported & summarized from a SMF 70 from

only one system, but then all the "This System" variables

are wrong, notably, SMF70LAC, the IBM 4HR AVG MSU, which

will contain ONLY the MSU from the one "This System".

This change compares TYPE70 and TYPE70PR to detect if

there are missing TYPE70 or TYPE70PR data, printing a

a PROC FREQ with missing systems identified, and printing

a log message that SMF70LAC will be wrong.


Change 35.049 Support for MAINVIEW FOR IMS 5.3 a/k/a IMF or CIMS which

VMACCIMS COMPATIBLY added these variables to the CIMSTRAN dataset:

Mar 12, 2017 TRNMSYS ='MQ*REMOTE*SYSTEM*NAME'

TRNDSYS ='DB2*REMOTE*SYSTEM*NAME'

TRNFLTRD='SOME*CALLS*NOT TRACED*FILTERS?'

TRNPRELD='PGM*WAS*PRELOADED'

TRNINFL ='TRN WAS*CAUGHT*INFLIGHT'

Was reserved change number until Sep 23, 2018


Change 35.048 Support for IWS Version 9.3, a/k/a TWS and was OPC, which

VMACOPC replaces subtype 23 with new subtype 66 with the original

Feb 24, 2017 variables plus these four new variables

TRLDURS23='DURATION'

TRLOID23 ='OPERATION*ID'

TRLOLDST23='OLD*STATUS'

TRLREADY23='START*DATETIME*WAIT*OPR'

The new subtype 66 record is output in the OPC23 dataset

so your reports won't have to be changed.

Thanks to Teuvo Virsu, TIETO,


Change 35.047 Support for IFCID 316 ACCESS CONTROL AUTH EXIT PARMS.

VMAC102


Feb 24, 2017
Change 35.046 Support for IFCID 125 Truncated Package Collection and

FORMATS Package Name fields, and new variables for Runtime

VMAC102 Adaptive Index in T102S125 dataset:

Feb 20, 2017 QW0125TI='INDEX*PROBING*RIDS IN*INDEX'

QW0125QI='INDEX*PROBING*RIDS*IN*KEYRANGE'

QW0125_TRSN='REASON*LEG*WAS*TERMINATED?'

QW0125_PRSN='REASON*LEG*NOT*PROBED?'

QW0125_ORSN='REASON*LEG*WAS*REORDERED?'

QW0125_FRSN='REASON*LEG*WAS*MARKED FULL?'
Change 35.045 ANALDB2R variable QWHSRELN format expanded from 3.1 to

ANALDB2R 4.1 to print full 10.1 Release value in reports.

Feb 20, 2017
Change 35.044 -The new ZRBCPU SMT Multithreading variables were always

VMACRMFV missing due to an invalid MXG test for LENLEFT.

Feb 20, 2017 -New variables found in the Dec 2016 Programmers Guide:

Dataset ZRBCPU:

CPC_CECNAME='CPC*CEC*NAME'

LPARHWGR='LPAR*HW*GROUP*NAME'

Dataset ZRBLCP:

LCPUHWLW='HW*GROUP*CAP*LIMIT'

LPARHWGR='LPAR*HW*GROUP*NAME'

-APAR OA58688 adds these new fields.

Thanks to MP Welch, Bank of America, USA.
Change 35.043 SMF74NID, the Network ID, contains 26 EBCDIC and 2 hex

VMAC74 bytes that don't "print pretty". Variable SMF74NIDTWO

Feb 20, 2017 keeps those two bytes, formatted $HEX4. for printing.

Thanks to Pierre Pascal Joulin, Societe Generale, FRANCE.


Change 35.042 Sample code that creates charts of resource group CPU

GRAFCAPS usage and capping.

Feb 17, 2017
Change 35.041 DCOLLECT format MGDCOSG adds new 6='6:COPYPOOL' value to

FORMATS map that value in variable DSGFTYPE.

Feb 17, 2017

Thanks to J. Alan Gray, CareFirstBlueCrossBlue Shield, USA.

Thanks to Stanley M. Helms, CareFirstBlueCrossBlue Shield, USA.
Change 35.040A IBM APAR OA51325 corrects invalid SMF 15 record missing

VMAC1415 the UCB segment causing VOLSER to be truncated to two

Feb 17, 2017 characters. No code change to support the corrections.
Change 35.040 Support for Velocity Software ZWRITE file z/VM MONWRITE

VMACVMXA records which have a new BEGINMTR value for each (hour)

VMXGINIT period, which caused the first interval of each (hour) to

Feb 15, 2017 be lost, because normal MONWRITE records have a single

BEGINMTR value for each file. But the ZWRITE records are

contiguous in spite of changed BEGINMTR, so this support

is enabled with %LET MXGZWRITE=YES; in SYSIN which

will set BEGINMTR only from the first instance so only

the very first interval is lost per day.

// EXEC MXGSASV9

//VMINPUT DD DSN=YOUR.ZWRITE.MONWRITE.DATA,DISP=SHR

//PDB DD DSN=YOUR.ZWRITE.PDB,DISP=OLD

//SYSIN DD *

%LET MXGZWRITE=YES;

%INCLUDE SOURCLIB(VMACVMXA,IMACKEEP);

_TESTVM /*READS VMINPUT */

Thanks to Scott Barry, SBBWorks Inc., USA.
Change 35.039 MQMQUEUE variable WQQTYPE is mapped by MG116QT format

FORMATS VALUE MG116QT

VMAC116 1='1:LOCAL'

Feb 15, 2017 2='2:MODEL'

3='3:ALIAS'

6='6:REMOTE'

7='7:CLUSTER'

-GMTOFF116 calculation revised correcting occasional

missing values in WQCLOSTI, WQOPENTI, and WQTTTIME.

(WQCLOSTI can be validly missing).

-APAR PI70580 corrects invalid WQBASENA variable values,

which seem to occur in every second segment in each

SMF record, but other segment's values are valid.

Thanks to Raymond Smith, Optum TECH, USA.

Thanks to Pietro Rosella, Canadian National Rails, CANADA
Change 35.038 MXG 34.04 added PROC DELETE DATA=:CIC after PDB.CICINTRV

CICINTRV had been created, intending to delete ONLY CICS Stats

VMXGCICI datasets to free up //WORK space for subsequent use, but

Feb 14, 2017 if CICINTRV was intentionally left in //WORK, it was then

unintentionally deleted by that colon modifier, and ITRM

expected it to be left in WORK as it had been previously.

Since no one had actually asked for this cleanup, it has

been removed from VMXGCIC. But, added at the bottom of

the CICINTRV member, inside a comment block, is the code

to delete all of those CICS Stats, if you do wish to.

Thanks to Don Barnard, North Carolina State Government, USA.

Thanks to Chris Weston, SAS Institute ITRM, USA.


Change 35.037 ASUMDB2P expected variables QPACDBRM/QPACPACK would be

ANALDB2R populated, but those bits were removed in DB2 V10, so now

ASUMDB2P PACKTYPE is blank.

Feb 14, 2017 -ANALD2R was not correctly rolling up the control break

totals in the Accounting SHORT report.
Change 35.036 VMXGSUM will now tell you with an MXGNOTE when it cannot

VMXGSUM use CLASS NWAY and why it cannot. There are two cases:

Feb 11, 2017 - Use of DESCENDING in the SUMBY

- same dataset name for input and output and no OUTCODE

specified

It will also now display the final setting of SUMBYCLASS.

Thanks to Tim Hare, Southwood Shared Resource Center, USA.
====== Changes thru 35.035 are in this MXG 35.02 dated Feb 10, 2017=====
Change 35.035 Protection for Invalid TPX Subtype 7 record with Segment

VMACTPX TPX07LEN=93 but only 44 bytes remain in the record. MXG

Feb 10, 2017 silently deleted the record, because of prior invalid 07x

Feb 14, 2017 causing zero obs in TPXAPLON Logon dataset. The first 44

are now INPUT, and the remainder conditionally input.

-Feb 14: Correction for undocumented 8 byte insert

in '06' and a blank in TPXSNAME.

-Feb 14: Each pair of subtype 01 TPXSTART records have the

same SMF time, but the second record is a continuation of

the first record, which is not supportable; a problem

report will be opened with TPX Support.

-TPX PTFS R088919 and R085818 correct some errors, while

CA Fix TR95030 corrects the bad subtype 1 records which

turned out to subtype 2 records with wrong subtype.

Thanks to Scott Wiig, USBank, USA.

Thanks to Paul Volpi, UHC, USA.


Change 35.034 Support for the BBMQ large segment record structure that

VMACBBMQ are created by the BMC BBM9MD73 utility program that

Feb 10, 2017 extracts the records from the history file for TYPEBBMQ

to then process. Both old and new format records are

supported with this change and there were no changes to

the MXG datasets.


Change 35.033 Logic to determine the begin/end of month was robusted

VMXGALOC and non-zero length MNTHKEEP will always display the

Feb 9, 2017 MONTH Libname value.
Change 35.032 Documentation Only. DCOLLECT records can contain the JOB

VMACDCOL and STEP and the TIME of the Creating JOB for DISP=NEW

Feb 9, 2017 datasets, but the EATTR option must be specified either

in the DATACLASS definition or with a DD statement.

Thanks to Paul Newton, IBM RDP Dallas, USA.
Change 35.031 Variable S42DSIOS='RW TO*METRO*MIRROR*SECONDARY' is added

VMACDB2 to dataset TYPE42DS, having been overlooked.

Feb 9, 2017

Thanks to Stephen Hoar, Lloyds Banking, ENGLAND


Change 35.030 DB2 statistics dataset DB2STAT4 QW0225_LMWRITE_REAL and

VMACDB2 _QW0225_LMCTYRL_REAL were incorrectly very large due to

Feb 7, 2017 a 4-byte misalignment.

Thanks to Giuseppe Giacomodonato, EPVTECH, ITALY.


Change 35.029 RACF SMF70DTP/RACFTYPE=6 segment was increased in length

VMAC80A from 124 to 136 but had not been protected for a change.

Feb 7, 2017 Three additional keyword variables ADDLKEY1-ADDLKEY3

are added to TYPE8010 and TYPE8013 datasets.

Thanks to Coen Wessels, GTS Infrastructure, SWITZERLAND.
Change 35.028 Support for RMF III dataset ZRBENC new "long name" fields

ASMRMFV that were added by z/OS 2.1 but not captured by ASMRMFV.

VMACRMFV Variables EDEPCKG EDEPROC EDEUSER EDETRXN ECEACCT were

Feb 6, 2017 increased in length and these new variables are kept:

EDESCHEDENV ='SCHEDULING*ENVIRONMENT*NAME'

EDESCHEDENVLN ='S E NAME LENGTH'

EDESUBSYSCOLLECT ='SUBSYSTEM*COLLECTION*NAME'

EDEPCKGLN ='PACKAGE*NAME*LENGTH'

EDEPROCLN ='PROCEDURE*NAME*LENGTH'

EDECLIENTIPADDR ='CLIENT*IP*ADDRESS'

EDECLIENTIPADDRLN ='CLIENT*IP*ADDRESS*LENGTH'

EDEUSERLN ='CLIENT*USERID*LENGTH'

EDETRXNLN ='CLIENT*TRANSACTION*NAME*LENGTH'

EDECLIENTWRKSTATION ='CLIENT*WORKSTATION'

EDECLIENTWRKSTALN ='CLIENT*WORKSTATION*LENGTH'

EDEACCTLN ='CLIENT*ACCOUNT*LENGTH'

Thanks to Scott Barry, SBBWorks Inc., USA.
Change 35.027 Support for DB2 NETEZZA DB2ACCT Q8AC Accumulated fields:

IMACDBNZ Q8ACINSC='INSERT*STATEMENTS*SENT TO IDAA*FROM DB2'

Feb 6, 2017 Q8ACUPDC='UPDATE*STATEMENTS*SEND TO IDAA*FROM DB2'

Q8ACDELC='DELETE*STATEMENTS*SEND TO IDAA*FROM DB2'

Q8ACDRPC='DROP*STATEMENTS*SEND TO IDAA*FROM DB2'

Q8ACCRTC='CREATE*STATEMENTS*SEND TO IDAA*FROM DB2'

Q8ACCMTC='COMMIT*STATEMENTS*SEND TO IDAA*FROM DB2'

Q8ACRBKC='ROLLBACK*STATEMENTS*SEND TO IDAA* FROM DB2'

Q8ACOPNC='OPEN*STATEMENTS*SEND TO IDAA*FROM DB2'

Q8ACROWI='ROWS*INSERTED*TO IDAA*BY DB2'

Q8ACROWU='ROWS*UPDATED*ON IDAA*BY DB2'

Q8ACROWD='ROWS*DELETED*ON IDAA*BY DB2'

Q8ACROWC='ROWS*RETURNED*BY IDAA*TO DB2'

These variables are output in DB2ACCT, but they appear

to be defective, as they are supposed to be ACCUMULATED

but the 2012 and 2013 test data I have has breaks in the

expected monotonic increase, so if you are interested in

these fields, please send current SMF 101 data so I can

investigate if the accumulation is now valid.
Change 35.026 If MXG detects Service Class Name of SYSOTHER, error msgs

UTILRMFI are printed when SMF 72 records are processed. SYSOTHER

Feb 1, 2017 should never happen; it is the fall thru service class

when WLM can't classify work and runs at the lowest DPRTY

in MTTW mode, and thus should NOT ever happen! Now, when

UTILRMFI is run to examine the problem, it will also read

the PDB.SMFINTRV or PDB.TYPE30_4 dataset to find what

tasks were classified into SYSOTHER, reporting JOB name,

READTIME, JESNR, and SRVCLASS and RPTCLASS. If there are

type 30 records they will be reported but there may not

be any, if no tasks actually went to the service classes,

or the workload is one where there is no type 30 record

(e.g., DDF). All workloads in your WLM classification

rules should have a default service class SPECIFIED:

-Unclassified work will default to one of two places

- Started Tasks default to SYSSTC

- All other work defaults to SYSOTHER

Neither is a good choice. SYSSTC runs at very high DP

and SYSOTHER runs at very LOW DP. While very low may be

appropriate for workloads you do not know, very high is

almost certainly not.

-Reports 1 thru 3 already exist.

-Report 4 is added to give you the job names, read times

jes numbers, service and report class where the service

class is SYSOTHER, from 30_4 and SMFINTRV.

-Report 5 is added to show you any DB2ACCT records that

may have landed in SYSOTHER as they may not be in a type

30 record.

-Report 6 is added to show you all tasks falling into

SYSSTC, from 30_4, SMFINTRV and 30_6.

-Report 7 is added as a table of CPU consumption by

service class and system, from TYPE72GO.

-Report 8 is added as a table of CPU consumption

by report class and system from TYPE72GO.


Change 35.025 Using the _VMINPUT macro to read VB z/VM MONWRITE data

VMACVMXA incorrectly set the length of VMDUSER to only one byte.

Feb 1, 2017

Thanks to Scott Barry, SBBWorks Inc., USA.


Change 35.024 SMF 120 Subtype 9 variables SM1209EV/EW/SM1209FI are not

VMAC120 kept. In TYP1209U detail dataset, they are output either

Feb 3, 2017 in new variables SM1209xxEJBDET or SM1209xxWEBDET, and in

datasets TYP1209R and TYP1209N they are summed and output

in SM1209xxEJB and SM1209xxWIB variables.

The TIME format was removed from the EW count variables.

Thanks to Giuseppe Giacomodonato, EPVTECH, ITALY.
Change 35.023 MXG 35.01. If UTILEXCL executed with //PDB DD DISP=OLD,

UTILEXCL only the NEW dictionary records read from SMF are used

Jan 29, 2017 to create the IMACEXCL, and old dictionary records are

lost; only the new records are output in PDB.CICSDICT.

(The step DATA _LCICDIC; SET _WCICDIC; to add the LABEL

was changed to SET _LCICDIC to correct this error.)

Thanks to Matthew Chappell, QLD Dept Transport Main Roads, AUSTRALIA
Change 35.022 ANCIENT syntax of DATETIME in SUMBY in user tailored

VMXGSUM invocation of VMXGSUM (pre MXG Version 21 example!) can

Jan 29, 2017 cause VMXGSUM, which is used EXTENSIVELY internally in

MANY MXG members, to fail, sometimes with only a message

WARNING: VARIABLE QWACBSC ALREADY EXISTS ON WORK.MXGSUM3

or it can ABEND with ERROR FUNCTION COMPBL TOO FEW ARGS.

Only three sites reported the error with MXG 35.01/34.34.

Primary exposure was this syntax,

SUMBY= . . .DATETIME . . . ,

ID= . . . QWACBSC . . . ,

DATETIME= QWACBSC,

which caused the output dataset variables QWACBSC and

DATETIME have missing values.

The correct syntax replaces DATETIME in the SUMBY= :

with the DATETIME= variable, and removes the DATETIME=

variable from the ID= argument,

This error was exposed in MXG 34.05 in Change 34.151 for

the CLASSNWAY update that is also corrected. But, even

though unlikely, this change detects the old syntax with

DATETIME in SUMBY= argument, changes to correct syntax,

and tells you what was done for you in a log note.

If you had DATETIME in the SUMBY= list and also did NOT

explicitly use the DROPDT=NO option, then DATETIME

variable is kept in the output dataset.

-Unrelated, this change adds the FLORCEIL parameter to

VMXGSUM so you can create interval start or end times as

you can do in VMXGDUR. Setting FLORCEIL=CDIL sets the END

time or FLORCEIL=FLOOR sets the START time, and the label

indicates START or END.

-Note: this internal MXG Change could be INCOMPATIBLE with

programs that worked perfectly previously; send your code

VMXGSUM invocation and we will update your code.

Thanks to Paul Volpi, UHC, USA.
Change 35.021 MXG 35.01, TYPE78PA variables R782LSMOxx and R782GFMOxxx

VMAC78 and R782GFFRxxx are incorrect; R782LSMOMIN should have

Jan 27, 2017 been INPUT before R782LSMONTME, but statement was lost

causing R782LSMOMIM UNINIT message.

Thanks to Paul Naddio, FISERV, USA.
Change 35.020 MXG 35.01. Spurious MXGWARN: VMXGSUM BACKLEVEL MXG 3434

VMXGSUM note has no impact; the VMXGDUM in 35.01 is correct, but

Jan 25, 2017 the VMXGVERS call was not updated with '35.01' text.
Change 35.019 -Support for changed SYTCPU with SYTNLPS=1 SEGLEN=48

VMACXAM that caused INVALID SEGMENT record, XAMSYT dataset.

Jan 26, 2017 -Support for new SYTLC3 segment in XAMSYS records

Mar 2, 2017 was added on March 2, adding these new variables:

CALLCKID='CALL*CHECKID'

INDEX ='TO MATCH*HISTORY DATA'

SECONDS ='SECONDS'

CALXSCNT='TOTAL*SPIN*TIMES*EXCLUSIVE'

CALXTIME='TOTAL*SPIN*TIME'

CALSSCNT='SPIN*TIMES*SHARED'

CALSTIME='SPIN*TIME*SHARED*MODE'

CALCADSH='CAD*INSTRUCTIONS*OBTAIN*LOCK'

CALCADEX='CAD*INSTRUCT*OBTAIN*EXCL LOCK'

-Support for new HSTME2 segment in XAMTCP was added

on March 2, changing only the length of DESCR to

60 bytes.

Thanks to Patricia Hansen, ADP, USA.
Change 35.018 An extraneous character in the SU_SEC format raised a

GRAFWRKX WARNING but did not cause an error, but ZIPTM, IFATM, and

Jan 26, 2017 ZIETM were not being properly summed, causing the ZIP ZAP


Yüklə 28,67 Mb.

Dostları ilə paylaş:
1   ...   15   16   17   18   19   20   21   22   ...   383




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©muhaz.org 2024
rəhbərliyinə müraciət

gir | qeydiyyatdan keç
    Ana səhifə


yükləyin