705.12
|
Chemical Admixtures for Concrete
|
Verify type and brand name of material is on QPL at the time of use.
Document in CMS.
|
Storage: Admixtures should be stored at concrete producer in such a manner to permit easy access for proper identification in weather resistant units.
Provide minimum QA sample of one (1) every 180 days per concrete plant, each material, each company. Minimum sample size one (1) quart.
|
705.15
|
High Molecular Weight Methacrylate (HMWM)
|
Verify type and brand name of material is on QPL at the time of use.
Document in CMS.
|
|
705.20
|
Non Shrink, Non Metallic Grout
|
Verify type and brand name of material is on QPL at the time of use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use 1notify District Testing and OMM for sampling requirements.
|
705.21
|
Quick Setting Concrete Mortar
|
Verify type and brand name of material is on QPL at the time of use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use 1notify District Testing and OMM for sampling requirements.
|
705.22
|
Non-shrink Mortar
|
Verify manufacturer is on the Approved List maintained by OMM.
Inspect for condition, appearance and dimension.
Make three (3) or more 3"x6" cylinders from keyway mix.
Ship to OMM Concrete Section.
Document in CMS.
|
Sample will be tested at 3, 7 and 28 days.
Do not open structure to traffic until a compressive strength of 5000 psi (34.5 MPa) is achieved.
|
705.23 A
|
Epoxy-urethane Sealers
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use obtain 1 qt (1 L) samples in a sealed container and send to OMM.
|
705.23 B
|
Non Epoxy Sealers
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use obtain 1 qt (1 L) samples in a sealed container and send to OMM.
|
705.24
|
Soluble Reactive Silicate
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
|
705.25
|
Gravity Fed Resin
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use obtain 1 qt (1 L) samples in a sealed container and send to OMM.
|
705.26
|
Epoxy injection Resin
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
|
706.01
|
Non-Reinforced Concrete Pipe
|
Assure products are supplied by a source on the Certified List for S-1074 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
Iif rejecting material because material non-performs or looks defective during use., notify District Testing and OMM, Cement and Concrete section,
|
706.02
|
Reinforced Concrete Circular Pipe
|
Assure products are supplied by a source on the Certified List for S-1074 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.03
|
Reinforced Concrete Pipe, Epoxy Coated
|
Assure products are supplied by a source on the Certified List for S-1074 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.04
|
Reinforced Concrete Elliptical Culvert,
Storm Drain and Sewer Pipe
|
Assure products are supplied by a source on the Certified List for S-1074 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.05
|
Precast Reinforced
Concrete Box Sections
|
Assure products are supplied by a source on the Certified List for S-1073 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.051
|
Precast Reinforced Concrete
Three-Sided Flat Topped Culverts
|
Assure products are supplied by a source on the Certified List for S-1073 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.052
|
Precast Reinforced Concrete Arch Sections
|
Assure products are supplied by a source on the Certified List for S-1073 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.06
|
Perforated Concrete Pipe
|
Assure products are supplied by a source on the Certified List for S-1074 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.07
|
Concrete Drain Tile
|
Assure products are supplied by a source on the Certified List for S-1074 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.08
|
Vitrified Clay Pipe
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, appearance and dimension.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.09
|
Clay Drain Tile
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, appearance and dimension.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Cement and Concrete section,
|
706.10
|
Bituminous pipe joint filler
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, appearance and dimension.
Document in CMS.
|
If rejecting material because material non-performs or looks defective during use, notify District Testing and OMM, Asphalt Concrete section, .
|
706.11
|
Resilient and Flexible Gasket Joints
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, appearance and dimension.
Document in CMS.
|
Notify District Testing and OMM, Structural Metals and Welding section, if rejecting material because material non-performs or looks defective during use.
|
706.12
|
Resilient and Flexible Joints
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, appearance and dimension.
Document in CMS.
|
Notify District Testing and OMM Structural Metals and Welding section, if rejecting material because material non-performs or looks defective during use.
|
706.13
|
Precast Reinforced Concrete Manhole Riser Sections, Catch Basins and Inlet Tops, and Temporary Barriers
|
Assure products are supplied by a source on the Certified List for S-1073 maintained by OMM
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
Notify District Testing and OMM, Cement and Concrete section, if rejecting material because material non-performs or looks defective during use.
|
706.14
|
Flexible Plastic Gaskets
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, appearance and dimension.
Document in CMS.
|
Notify District Testing and OMM, Structural Metals and Welding section, if rejecting material because material non-performs or looks defective during use.
|
706.15
|
Precast Reinforced Concrete Outlets
|
Assure products are supplied by a source on the Certified List for S-1073 maintained by OMM
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Document in CMS.
|
Notify District Testing and OMM, Cement and Concrete section, if rejecting material because material non-performs or looks defective during use.
|
707.01
|
Metallic Coated Corrugated Steel Conduits and Underdrains
[½ inch and 1/4 depth corrugations]
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.02
|
Metallic Coated Corrugated Steel Conduits
[1 inch depth corrugation]
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.03
|
Structural Plate Corrugated Steel Structures
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.04
|
Precoated, Galvanized Steel Culverts
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and cracks.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use
|
707.05
705.07
|
Bituminous Coated Corrugated Steel Pipe and Arches with Paved Invert
[½ inch depth corrugations]
[1 inch depth corrugations]
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.10
|
Steel Tubing
Square and Rectangular
|
Generally a fabricated component received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.11
|
Mortar Lined Corrugated Steel Pipe
[any corrugation depth]
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.12
|
Corrugated Steel Spiral Rib Conduits
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use
|
707.13
707.14
|
Bituminous Lined Corrugated Steel Pipe
[½ depth corrugations]
[1 depth corrugations]
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.15
|
Corrugated Steel Box Culverts
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.21
|
Corrugated Aluminum Alloy Conduits and Underdrains
[1/4, 7/16 & ½ inch depth corrugations]
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimension and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.22
|
Corrugated Aluminum Alloy Conduits
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimension and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.23
|
Aluminum Alloy Structural Plate Conduits
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.24
|
Corrugated Aluminum Spiral Rib Conduits
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.25
|
Corrugated Aluminum Box Culverts
|
Products will be supplied by a source on the Certified List for S-1019 maintained by OMM.
Received with TE-24.
Check dimensions and markings.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
707.31
707.32
707.33
|
Polyethylene Corrugated Pipe
|
Products will be supplied by a source on the Certified List for S-1066 maintained by OMM.
Received with TE-24.
Check dimension and markings.
Document in CMS.
|
Notify District Testing and OMM, asphalt section, if rejecting material because material non-performs or looks defective during use.
|
707.41
|
Polyvinyl Chloride Plastic Pipe
|
If material is shipped with TE24, accept based on inspection of material for type, condition and dimension.
Document in CMS.
If no TE24, accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data.
Document in CMS
|
Notify District Testing if rejecting material.
|
707.42
|
Polyvinyl Chloride Corrugated Smooth Interior Pipe
|
If material is shipped with TE24, accept based on inspection of material for type, condition and dimension.
Document in CMS.
If no TE24, accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data.
Document in CMS
|
Notify District Testing if rejecting material.
|
707.43
|
Polyvinyl Chloride Profile Wall Pipe
|
If material is shipped with TE24, accept based on inspection of material for type, condition and dimension.
Document in CMS.
If no TE24, accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data.
Document in CMS
|
|