B.I.3. INSULATION WORKS
B.I.3.a
|
WATERPROOFING
|
sqm
|
|
|
|
|
|
|
For details check Annex no.2.B and the architectural details DT1b, DT1c, DT2b, DT3b, DT4b, DT4b, DT5b and DT5c.
|
B.I.3.b
|
THERMAL INSULATION
|
sqm
|
|
|
|
|
|
|
For details check Annex no.2.B and the architectural details DT1a, DT1b, DT2b DT3b, DT4b, DT5b, DT5c, DT11b and D7.
|
PHASE B.II
|
INSTALLATIONS, LIGHTWIGHTE PARTITIONS, FINISHES
|
B.II.1. INSTALLATION WORKS
|
B.II.1.a
|
SANITARY WARE INSTALLATIONS
|
|
|
|
|
|
|
|
For details check Annex no.2.B and the installation drawings IS001.Underground pipes below the 0.00, IS002.Ground floor plan, IS003.First floor plan, IS004.Split floor plan
|
B.II.1.a.1
|
SPRINKLERS FIRE SYSTEM
|
|
Sprinkler
|
piece
|
40
|
|
|
|
|
|
Standard Sprinkler, mounted pendent head
- K factor 80
- t=68°C
- conection 1/2"
- standard response
- presure 1bar
|
|
Steel pipe
|
ml
ml
|
|
|
|
|
|
|
Steel pipes Pn16,
- including fittings
- DN25
- DN32
- DN40
- DN50
- DN100
|
B.II.1.a.2
|
SEWAGE
|
|
Sewage pipes, overground
|
ml
|
|
|
|
|
|
|
Polypropylene pipes for sewage, belled joint and elastomere backing, including ramifications
D= 32 mm
D= 40 mm
D= 50mm
D= 110 mm
|
|
Floor trap
|
piece
|
2
1
|
|
|
|
|
|
Floor water trap with lateral / vertical discharge
D= 50 mm
D= 110 mm
|
|
Cleaning tube
|
piece
|
4
|
|
|
|
|
|
Cleaning tube , for interior drainage
D= 110 mm
|
|
Aerator with membrane
|
piece
|
2
|
|
|
|
|
|
Aerator with membrane for ventilation
D= 50 mm
|
|
Grease separator
|
piece
|
1
|
|
|
|
|
|
Grease separator, mounted under washbasin
|
|
Direction flap
|
piece
|
1
|
|
|
|
|
|
Direction flap for sewage
D= 200 mm
|
B.II.1.a.3
|
RAINWATER
|
|
Rainwater pipes, overground
|
ml
|
|
|
|
|
|
|
Polypropylene pipes for rainwater, belled joint and elastomere backing, including ramifications
D= 110 mm
|
|
Reciver rain water
|
piece
|
10
|
|
|
|
|
|
Reciver rain water for green area
D= 110 mm
|
|
Cleaning tube
|
piece
|
5
|
|
|
|
|
|
Cleaning tube , for interior drainage
D= 110 mm
|
|
Direction flap
|
piece
|
1
|
|
|
|
|
|
Direction flap for sewage
D= 200 mm
|
B.II.1.a.4
|
SERVICE WATER
|
|
Potable water pipes - overground
|
ml
|
|
|
|
|
|
|
Polypropylene pipes (PP- R) PN16 for cold and hot water
(including fittings and clamps),
D=20mm
D=25mm
D=32mm
D=40mm
|
|
Irrigation system
|
piece
|
1
|
|
|
|
|
|
Irrigation system, 200 square meters surface, including, pipes, fittings , automation.
|
|
Butterfly valve
|
piece
|
2
2
6
6
|
|
|
|
|
|
Butterfly valve
D= 20 mm
D= 25 mm
D= 32 mm
D= 40 mm
|
|
Backflow preventer
|
piece
|
2
|
|
|
|
|
|
Backflow preventer
D= 40 mm
|
|
Submersible pump
|
piece
|
1
|
|
|
|
|
|
Submersible pump for Irrigation system;
Flow=1.5l/s;
Presure=4 bar
|
|
Water meter
|
piece
|
1
|
|
|
|
|
|
Water meter for cold water
D= 25 mm
|
B.II.1.a.5
|
POTABLE WATER
|
|
Potable water pipes - overground
|
ml
|
|
|
|
|
|
|
Polypropylene pipes (PP- R) PN16 for cold and hot water
(including fittings and clamps),
D=20mm
D=25mm
|
|
Water meter
|
piece
|
1
|
|
|
|
|
|
Water meter for cold water
D= 25 mm
|
|
Butterfly valve
|
piece
|
7
8
|
|
|
|
|
|
Butterfly valve
D= 20 mm
D= 25 mm
|
|
Expansion tank
|
piece
|
1
|
|
|
|
|
|
Expansion tank;
Capacitay: 8 liters;
|
|
Recirculation pump
|
piece
|
1
|
|
|
|
|
|
Recirculation pump for hot water;
Flow :0,5 mc/h
Presure: 0.65bar
|
|
Backflow preventer
|
piece
|
1
|
|
|
|
|
|
Backflow preventer
D= 25 mm
|
B.II.1.b
|
ELECTRICAL INSTALLATIONS
|
For details consult Annex no.2.B. and drawing from the installations: IE001. Groundfloor lighting layout, IE002. Groundfloor sockets layout, IE003. First floor lighting layout, IE004. First floor sockets layout, IE005. Attic lighting layout and IE006. Attic sockets layout.
|
B.II.1.b.1
|
EXTERIOR ELECTRICAL INSTALLATIONS
|
For details consult Annex nr.2.B. It is noted that the electric wiring below the level of 0.00 was achieved in the previous phase of EXPO 2015, for connection shall consult drawings provided by official authority, but also provided the purchaser.( IE001. Groundfloor lighting layout, IE002. Groundfloor sockets layout, IE003. First floor sockets layout, IE004. First floor sockets layout, IE005. Attic lighting layout şi IE006. Attic sockets layout and A13.Lighting and sound – ground floor, A14 Lighting and sound – first floor and A15 Lighting and sound – split level floor.)
|
|
Protective PVC tube, D=150mm
|
ml
|
|
|
|
|
|
|
Protective tube for electrical cables;
According EN 50086-1, IEC 614-205.
|
|
Protective PVC tube, D=90mm
|
ml
|
|
|
|
|
|
|
Protective tube for electrical cables;
According EN 50086-1, IEC 614-205.
|
|
Flat conductor OLZn 40x4
|
ml
|
|
|
|
|
|
|
Zinc credited minimum 70 µm
According DIN EN 50164-2, VDE 185-305 (IEC 62305).
|
B.II.1.b.2
|
INTERIOR ELECTRICAL INSTALLATIONS
|
For details consult Annex nr.2.B. end drawing IE001. Groundfloor lighting layout, IE002. Groundfloor sockets layout, IE003. First floor sockets layout, IE004. First floor sockets layout, IE005. Attic lighting layout and IE006. Attic sockets layout and A13.Lighting and sound – ground floor, A14 Lighting and sound – first floor, A15 Lighting and sound – split level floor, A16. Electrical utilities – ground floor plan, A17. Electrical utilities – first floor plan and A18. Electrical utilities – split floor plan
|
|
Frame, bolster and box for 4 modules, equipped with 2
modular sockets 16A/230V, sunken mounted, IP20;
|
piece
|
14
|
|
|
|
|
|
Located in multipurpose hall
Technical Specifications: For modular plugs
|
|
Floor box, for 20 module , equipped with 4 white
modular sockets 2P+PE, 2xRJ45 Cat6 sockets and
VGA socket;
|
piece
|
17
|
|
|
|
|
|
Located in multipurpose hall, administration, general commissioner office
Technical Specifications: For modular plugs
|
|
Floor box, for 20 module , equipped with 4 white
modular sockets 2P+PE, 2xRJ45 Cat6 sockets;
|
piece
|
6
|
|
|
|
|
|
Located in multipurpose hall
Technical Specifications: For modular plugs
|
|
Single socket;
|
piece
|
6
|
|
|
|
|
|
Technical requirements: 2P+N / 16A/230V, IP20;
|
|
Double socket;
|
piece
|
26
|
|
|
|
|
|
Technical requirements: 2P+N / 16A/230V, IP20;
|
|
Single socket with protecting cover;
|
piece
|
3
|
|
|
|
|
|
Technical requirements: 2P+N / 16A/230V, IP20;
|
|
Electric panel pumping the lake station;
|
piece
|
1
|
|
|
|
|
|
Set in the water control station
Technical Specifications: Electrical panel pond pump station, surface mounting, manufacturing metal door with lock full,> IP65;
|
|
Electric panel climatizer;
|
piece
|
1
|
|
|
|
|
|
Set in the storage area
Technical Specifications: Electrical panel consumer climate, surface mounting, manufacturing metal door with lock full,> IP40;
|
|
Solar charger
|
|
|
|
|
|
|
|
80A
|
|
Junction box;
|
|
79
|
|
|
|
|
|
Technical Specifications: junction box and connection cable assembly bed;
|
|
Cable tray 60x200 mm;
|
piece
|
15
|
|
|
|
|
|
Specifications: cable ducts 60x200 mm , ceiling mounted, galvanized perforated sheet;
|
|
Cable tray 60x300 mm;
|
piece
|
5
|
|
|
|
|
|
Specifications: cable ducts 60x300 mm, ceiling mounted, galvanized perforated sheet;
|
|
Cable tray 60x400 mm;
|
piece
|
6
|
|
|
|
|
|
Specifications: cable ducts 60x400 mm, floor mounted, galvanized perforated sheet;
|
|
Bend 90° 60x400 mm;
|
piece
|
2
|
|
|
|
|
|
Technical Specifications: 60x400 mm 90 ° bend, floor mounted, galvanized perforated sheet;
|
|
90° curve for cable tray
60x300 mm;
|
piece
|
1
|
|
|
|
|
|
Technical Specifications: Curve 90 ° 60 x 300 mm, mounted in the floor, galvanized perforated sheet;
|
|
Cable tray 60x200 mm;
|
piece
|
8
|
|
|
|
|
|
Specifications: cable ducts 60x200 mm, floor mounted, galvanized perforated sheet;
|
|
90° curve for cable tray 60x200 mm;
|
piece
|
1
|
|
|
|
|
|
Technical Specifications: Curve 90 ° 60 x 300 mm, mounted in the floor, galvanized perforated sheet;
|
|
"T" split for cable tray 60x200 mm;
|
piece
|
1
|
|
|
|
|
|
Technical Specifications: Branch "T" 60x200 mm, mounted in the floor, galvanized perforated sheet;
|
|
"T" split for cable tray 60x400 mm;
|
piece
|
3
|
|
|
|
|
|
Technical Specifications: Branch "T" 60x400 mm, mounted in the floor, galvanized perforated sheet;
|
|
Electric panel Floor 1;
|
piece
|
1
|
|
|
|
|
|
Personal locker located
Technical Specifications: Electrical panel 1st floor, surface mounting, manufacturing metal door with lock full,> IP40;
|
|
Electric panel kitchen;
|
piece
|
1
|
|
|
|
|
|
Placed in the kitchen + storage
Technical Specifications: Electrical cabinet kitchen surface mounting, manufacturing metal door with lock full,> IP40;
|
|
Support frame and dose for 2 modules, equipped with one socket (2 modules) with protective contact 16A/230V,
flush mountable, IP20;
|
piece
|
1
|
|
|
|
|
|
Placed in the kitchen + storage
Technical Specifications: For modular plugs
|
|
Support frame and dose for 6 modules, equipped with three sockets (2 modules) with protective contact 16A/230V, flush mountable, IP20;
|
piece
|
7
|
|
|
|
|
|
Placed in the kitchen + storage
Technical Specifications: For modular plugs
|
|
Support frame and dose for 8 modules, equipped with four
sockets (2 modules) with protective contact 16A/230V,
flush mountable, IP20;
|
piece
|
1
|
|
|
|
|
|
Placed in the kitchen + storage
Technical Specifications: For modular plugs
|
|
Pole switch with frame and unit dose;
|
piece
|
12
|
|
|
|
|
|
Technical Specifications: Single Pole Switch 10A / 230V, flush mountable, IP 20
|
|
Double pole switch with frame and unit dose;
|
piece
|
12
|
|
|
|
|
|
Technical Specifications: Single Pole Switch 10A / 230V, flush mountable, IP 20;
|
|
Two-way switch with frame and unit dose;
|
piece
|
16
|
|
|
|
|
|
Technical Specifications: Switch-scale head 10A / 230V, flush mountable, IP 20;
|
|
General electric panel;
|
piece
|
1
|
|
|
|
|
|
Technical Specifications: General Electric panel, surface mounting, manufacturing metal door with lock full,> IP40;
|
|
Single phase imput/output UPS 6 kVA / 4 kW
|
piece
|
1
|
|
|
|
|
|
Technical Specifications: UPS UPS 6kVA / 4kW;
|
|
Electric panel UPS.
|
piece
|
1
|
|
|
|
|
|
Technical Specifications: Electrical panel UPS, surface mounting, manufacturing metal door with lock full,> IP40;
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 4x150+70sqmm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, and VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 4x70+35sqmm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 4x35+16sqmm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 5x16smm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 5x6sqmm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 5x4sqmm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 5x2.5sqmm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 3x10sqmm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, and VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 3x2.5sqmm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, and VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Power cables insulated crosslinked and thermoplastic
olyethylene jacket, halogen free, low smoke emission
(LSFH) section 3x1.5sqmm
|
ml
|
|
|
|
|
|
|
Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;
According CEI 60228, HD 604, and VDE 0276-604, EN 60266-2-4, EN50267-2-2.
|
|
Protective plastic tube, fire retardant, halogen free,
D=63mm
|
ml
|
|
|
|
|
|
|
Protective tube for electrical cables;
According EN 50086-1, IEC 614-205.
|
|
Protective plastic tube, fire retardant, halogen free,
D=50mm
|
ml
|
|
|
|
|
|
|
Protective tube for electrical cables;
According EN 50086-1, IEC 614-205.
|
|
Protective plastic tube, fire retardant, halogen free,
D=32mm
|
ml
|
|
|
|
|
|
|
Protective tube for electrical cables;
According EN 50086-1, IEC 614-205.
|
|
Protective plastic tube, fire retardant, halogen free,
D=25mm
|
ml
|
|
|
|
|
|
|
Protective tube for electrical cables;
According EN 50086-1, IEC 614-205.
|
|
Protective plastic tube, fire retardant, halogen free,
D=20mm
|
ml
|
|
|
|
|
|
|
Protective tube for electrical cables;
According EN 50086-1, IEC 614-205.
|
|
Protective plastic tube, fire retardant, halogen free,
D=16mm
|
ml
|
|
|
|
|
|
|
Protective tube for electrical cables;
According EN 50086-1, IEC 614-205.
|
B.II.1.b.3
|
|