Annex no a specifications for the romania pavilion at expo 2015 milano, italy



Yüklə 1,53 Mb.
səhifə2/16
tarix03.01.2022
ölçüsü1,53 Mb.
#34886
1   2   3   4   5   6   7   8   9   ...   16
B.I.3. INSULATION WORKS


B.I.3.a

WATERPROOFING

sqm



















For details check Annex no.2.B and the architectural details DT1b, DT1c, DT2b, DT3b, DT4b, DT4b, DT5b and DT5c.

B.I.3.b

THERMAL INSULATION


sqm



















For details check Annex no.2.B and the architectural details DT1a, DT1b, DT2b DT3b, DT4b, DT5b, DT5c, DT11b and D7.

PHASE B.II


INSTALLATIONS, LIGHTWIGHTE PARTITIONS, FINISHES


B.II.1. INSTALLATION WORKS

B.II.1.a

SANITARY WARE INSTALLATIONS






















For details check Annex no.2.B and the installation drawings IS001.Underground pipes below the 0.00, IS002.Ground floor plan, IS003.First floor plan, IS004.Split floor plan

B.II.1.a.1

SPRINKLERS FIRE SYSTEM





Sprinkler


piece

40
















Standard Sprinkler, mounted pendent head

- K factor 80

- t=68°C

- conection 1/2"

- standard response

- presure 1bar






Steel pipe


ml

ml




















Steel pipes Pn16,

- including fittings

- DN25

- DN32


- DN40

- DN50


- DN100

B.II.1.a.2

SEWAGE





Sewage pipes, overground


ml



















Polypropylene pipes for sewage, belled joint and elastomere backing, including ramifications

D= 32 mm


D= 40 mm

D= 50mm


D= 110 mm




Floor trap


piece

2

1


















Floor water trap with lateral / vertical discharge

D= 50 mm


D= 110 mm




Cleaning tube


piece

4
















Cleaning tube , for interior drainage

D= 110 mm







Aerator with membrane

piece

2
















Aerator with membrane for ventilation

D= 50 mm





Grease separator

piece

1
















Grease separator, mounted under washbasin




Direction flap

piece

1
















Direction flap for sewage

D= 200 mm



B.II.1.a.3

RAINWATER





Rainwater pipes, overground



ml



















Polypropylene pipes for rainwater, belled joint and elastomere backing, including ramifications

D= 110 mm






Reciver rain water



piece

10
















Reciver rain water for green area

D= 110 mm






Cleaning tube



piece

5
















Cleaning tube , for interior drainage

D= 110 mm






Direction flap



piece

1
















Direction flap for sewage

D= 200 mm



B.II.1.a.4

SERVICE WATER





Potable water pipes - overground


ml



















Polypropylene pipes (PP- R) PN16 for cold and hot water

(including fittings and clamps),

D=20mm

D=25mm


D=32mm

D=40mm





Irrigation system



piece

1
















Irrigation system, 200 square meters surface, including, pipes, fittings , automation.




Butterfly valve

piece

2

2



6

6

















Butterfly valve

D= 20 mm


D= 25 mm

D= 32 mm


D= 40 mm




Backflow preventer


piece

2
















Backflow preventer

D= 40 mm






Submersible pump


piece

1
















Submersible pump for Irrigation system;

Flow=1.5l/s;

Presure=4 bar





Water meter


piece

1
















Water meter for cold water

D= 25 mm


B.II.1.a.5

POTABLE WATER





Potable water pipes - overground


ml



















Polypropylene pipes (PP- R) PN16 for cold and hot water

(including fittings and clamps),

D=20mm

D=25mm





Water meter


piece

1
















Water meter for cold water

D= 25 mm





Butterfly valve


piece

7

8


















Butterfly valve

D= 20 mm


D= 25 mm




Expansion tank


piece

1
















Expansion tank;

Capacitay: 8 liters;






Recirculation pump


piece

1
















Recirculation pump for hot water;

Flow :0,5 mc/h

Presure: 0.65bar





Backflow preventer


piece

1
















Backflow preventer

D= 25 mm


B.II.1.b

ELECTRICAL INSTALLATIONS

For details consult Annex no.2.B. and drawing from the installations: IE001. Groundfloor lighting layout, IE002. Groundfloor sockets layout, IE003. First floor lighting layout, IE004. First floor sockets layout, IE005. Attic lighting layout and IE006. Attic sockets layout.

B.II.1.b.1

EXTERIOR ELECTRICAL INSTALLATIONS

For details consult Annex nr.2.B. It is noted that the electric wiring below the level of 0.00 was achieved in the previous phase of EXPO 2015, for connection shall consult drawings provided by official authority, but also provided the purchaser.( IE001. Groundfloor lighting layout, IE002. Groundfloor sockets layout, IE003. First floor sockets layout, IE004. First floor sockets layout, IE005. Attic lighting layout şi IE006. Attic sockets layout and A13.Lighting and sound – ground floor, A14 Lighting and sound – first floor and A15 Lighting and sound – split level floor.)




Protective PVC tube, D=150mm

ml



















Protective tube for electrical cables;

According EN 50086-1, IEC 614-205.






Protective PVC tube, D=90mm


ml



















Protective tube for electrical cables;

According EN 50086-1, IEC 614-205.






Flat conductor OLZn 40x4


ml



















Zinc credited minimum 70 µm

According DIN EN 50164-2, VDE 185-305 (IEC 62305).



B.II.1.b.2

INTERIOR ELECTRICAL INSTALLATIONS

For details consult Annex nr.2.B. end drawing IE001. Groundfloor lighting layout, IE002. Groundfloor sockets layout, IE003. First floor sockets layout, IE004. First floor sockets layout, IE005. Attic lighting layout and IE006. Attic sockets layout and A13.Lighting and sound – ground floor, A14 Lighting and sound – first floor, A15 Lighting and sound – split level floor, A16. Electrical utilities – ground floor plan, A17. Electrical utilities – first floor plan and A18. Electrical utilities – split floor plan




Frame, bolster and box for 4 modules, equipped with 2

modular sockets 16A/230V, sunken mounted, IP20;




piece

14
















Located in multipurpose hall

Technical Specifications: For modular plugs







Floor box, for 20 module , equipped with 4 white

modular sockets 2P+PE, 2xRJ45 Cat6 sockets and

VGA socket;


piece

17
















Located in multipurpose hall, administration, general commissioner office

Technical Specifications: For modular plugs






Floor box, for 20 module , equipped with 4 white

modular sockets 2P+PE, 2xRJ45 Cat6 sockets;




piece

6
















Located in multipurpose hall

Technical Specifications: For modular plugs







Single socket;

piece

6
















Technical requirements: 2P+N / 16A/230V, IP20;




Double socket;

piece

26
















Technical requirements: 2P+N / 16A/230V, IP20;




Single socket with protecting cover;

piece

3
















Technical requirements: 2P+N / 16A/230V, IP20;




Electric panel pumping the lake station;

piece

1
















Set in the water control station

Technical Specifications: Electrical panel pond pump station, surface mounting, manufacturing metal door with lock full,> IP65;






Electric panel climatizer;

piece

1
















Set in the storage area

Technical Specifications: Electrical panel consumer climate, surface mounting, manufacturing metal door with lock full,> IP40;






Solar charger






















80A




Junction box;




79
















Technical Specifications: junction box and connection cable assembly bed;




Cable tray 60x200 mm;


piece

15
















Specifications: cable ducts 60x200 mm , ceiling mounted, galvanized perforated sheet;




Cable tray 60x300 mm;

piece

5
















Specifications: cable ducts 60x300 mm, ceiling mounted, galvanized perforated sheet;




Cable tray 60x400 mm;


piece

6
















Specifications: cable ducts 60x400 mm, floor mounted, galvanized perforated sheet;




Bend 90° 60x400 mm;


piece

2
















Technical Specifications: 60x400 mm 90 ° bend, floor mounted, galvanized perforated sheet;





90° curve for cable tray

60x300 mm;



piece

1
















Technical Specifications: Curve 90 ° 60 x 300 mm, mounted in the floor, galvanized perforated sheet;




Cable tray 60x200 mm;


piece

8
















Specifications: cable ducts 60x200 mm, floor mounted, galvanized perforated sheet;




90° curve for cable tray 60x200 mm;


piece

1
















Technical Specifications: Curve 90 ° 60 x 300 mm, mounted in the floor, galvanized perforated sheet;




"T" split for cable tray 60x200 mm;


piece

1
















Technical Specifications: Branch "T" 60x200 mm, mounted in the floor, galvanized perforated sheet;




"T" split for cable tray 60x400 mm;


piece

3
















Technical Specifications: Branch "T" 60x400 mm, mounted in the floor, galvanized perforated sheet;




Electric panel Floor 1;


piece

1
















Personal locker located

Technical Specifications: Electrical panel 1st floor, surface mounting, manufacturing metal door with lock full,> IP40;






Electric panel kitchen;


piece

1
















Placed in the kitchen + storage

Technical Specifications: Electrical cabinet kitchen surface mounting, manufacturing metal door with lock full,> IP40;






Support frame and dose for 2 modules, equipped with one socket (2 modules) with protective contact 16A/230V,

flush mountable, IP20;



piece

1
















Placed in the kitchen + storage

Technical Specifications: For modular plugs






Support frame and dose for 6 modules, equipped with three sockets (2 modules) with protective contact 16A/230V, flush mountable, IP20;

piece

7
















Placed in the kitchen + storage

Technical Specifications: For modular plugs






Support frame and dose for 8 modules, equipped with four

sockets (2 modules) with protective contact 16A/230V,

flush mountable, IP20;


piece

1
















Placed in the kitchen + storage

Technical Specifications: For modular plugs






Pole switch with frame and unit dose;


piece

12
















Technical Specifications: Single Pole Switch 10A / 230V, flush mountable, IP 20




Double pole switch with frame and unit dose;


piece

12
















Technical Specifications: Single Pole Switch 10A / 230V, flush mountable, IP 20;




Two-way switch with frame and unit dose;


piece

16
















Technical Specifications: Switch-scale head 10A / 230V, flush mountable, IP 20;




General electric panel;


piece

1
















Technical Specifications: General Electric panel, surface mounting, manufacturing metal door with lock full,> IP40;




Single phase imput/output UPS 6 kVA / 4 kW


piece

1
















Technical Specifications: UPS UPS 6kVA / 4kW;




Electric panel UPS.


piece

1
















Technical Specifications: Electrical panel UPS, surface mounting, manufacturing metal door with lock full,> IP40;




Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 4x150+70sqmm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, and VDE 0276-604, EN 60266-2-4, EN50267-2-2.







Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 4x70+35sqmm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.






Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 4x35+16sqmm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.






Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 5x16smm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.






Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 5x6sqmm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.






Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 5x4sqmm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.






Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 5x2.5sqmm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, VDE 0276-604, EN 60266-2-4, EN50267-2-2.






Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 3x10sqmm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, and VDE 0276-604, EN 60266-2-4, EN50267-2-2.






Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 3x2.5sqmm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, and VDE 0276-604, EN 60266-2-4, EN50267-2-2.






Power cables insulated crosslinked and thermoplastic

olyethylene jacket, halogen free, low smoke emission

(LSFH) section 3x1.5sqmm


ml



















Cable connection for electric panel / final receiver, mounted in protective tube or cable ducts, Un=0.6/1kV;

According CEI 60228, HD 604, and VDE 0276-604, EN 60266-2-4, EN50267-2-2.






Protective plastic tube, fire retardant, halogen free,

D=63mm



ml



















Protective tube for electrical cables;

According EN 50086-1, IEC 614-205.






Protective plastic tube, fire retardant, halogen free,

D=50mm


ml



















Protective tube for electrical cables;

According EN 50086-1, IEC 614-205.






Protective plastic tube, fire retardant, halogen free,

D=32mm


ml



















Protective tube for electrical cables;

According EN 50086-1, IEC 614-205.






Protective plastic tube, fire retardant, halogen free,

D=25mm


ml



















Protective tube for electrical cables;

According EN 50086-1, IEC 614-205.






Protective plastic tube, fire retardant, halogen free,

D=20mm


ml



















Protective tube for electrical cables;

According EN 50086-1, IEC 614-205.






Protective plastic tube, fire retardant, halogen free,

D=16mm


ml



















Protective tube for electrical cables;

According EN 50086-1, IEC 614-205.



B.II.1.b.3