R4-021671 General corrections to TS 25.141 (CR 257r1 to 25.141 Rel-4) (Siemens)
R4-021672 General corrections to TS 25.141 (CR 258r1 to 25.141 Rel-5) (Siemens)
Decision: The CRs are agreed
R4-021556 General Release 5 corrections (CR 259 to 25.141 Rel-5) (Siemens)
No comments
Decision: The CR is agreed
R4-021557 Transmit intermodulation test correction (CR 260 to 25.141 Rel-4) (Siemens)
R4-021558 Transmit intermodulation test correction (CR 261 to 25.141 Rel-5) (Siemens)
Moray Rumnay (Agilent) noted The requirement "the width of the intermod product should be taken into account" is unclear; from a measurement point of view is not obvious how it has to be taken into account when such a wide bandwidth signal falls at the end of the inband test band. Part of the signal would be measured with the inband test procedure and part with the out of band procedure. After off line discussions, it was agreed to keep the CR as is and elaborate a more precise way of running the test in future meetings
Decision: The CRs are agreed