·Earthquake zone on the plate boundary
|
tarix | 21.08.2018 | ölçüsü | 445 b. | | #73727 |
|
·Earthquake zone on the plate boundary -New Zealand, USA, Japan (Earthquake-resistant advanced countries)
◈ Kobe earthquake, Japan
- Year of occurrence : 1989 - Year of occurrence : 1989 - Magnitude : 7.1 - ·Minor damage: 89
- ·Major damage: 11
- Date of occurrence : Jan 17,1994 - Date of occurrence : Jan 17,1994 - Casualty : 57 people - Wounded : 90,000 people
Road standard specifications, Ministry of Construction, 1992 Road standard specifications, Ministry of Construction, 1992 Road bridge design criteria, Ministry of construction & Transportation, 2000 Road bridge design criteria, Ministry of construction & Transportation, 2005
Purpose of earthquake-resistant design Purpose of earthquake-resistant design - Securing the quake-proof ability in order to minimize the damage of the bridge caused by the earthquake
Basic concept of earthquake-resistant design criteria - Minimizing casualties.
- Allowing partial damage in bridge members but preventing entire collapse in case of earthquakes.
- Making it possible to perform the basic function of the bridge in case of earthquake.
- The Design Criteria can be applied to all area in South Korea.
- A creative work can be acknowledged to develop more advanced design even though it does not follow the rule.
The existing earthquake-resistant design : increasing the strength of the structure - Beginning of the modern earthquake resistant design caused by Messina earthquake in Italy with magnitude 7.5 in 1908
- Building the structure stronger can resist from the horizontal load generated by earthquakes
- Aiming the prevention of collapse
- Allowing the structural damage
- Increasing seismic movement of the inside of the structure
A new earthquake-resistant design : controlling the seismic movement of the structure - Seismic movement control system reducing the required strength by using seismic isolation system or energy dissipation system
◈ Approach of the earthquake-proof system ◈ Approach of the earthquake-proof system
◈ Application of aseismatic system ◈ Application of aseismatic system - The system prevents the earthquake and terminates its energy. It makes smaller energy come into the structure reliving the remaining energy.
· Long cyclic function : Flexible horizontal transformation ability · Long cyclic function : Flexible horizontal transformation ability · Vertical load support function: sufficient load supporting ability - Supporting up to maximum 147 Mpa/cm2
· Seismic isolation support integrated with damping function · Seismic isolation support integrated with damping function · Support injecting lead with excellent plasticity
·Oil damper ·Oil damper - Using low viscosity fluid
- Low dependency on temperature
- Complicated inner structure
1) ERJ 1) ERJ - Use : long-span vertical expansion joint - Expansion : 300 ~ 800mm
Thank you so much!!