Heavy-ion collisions p-p data taking



Yüklə 445 b.
tarix01.08.2018
ölçüsü445 b.
#64790





heavy-ion collisions



p-p data taking



highly-saturated avalanche operation



preliminary studies with cosmic rays

  • test on 50x50 cm2 RPC

  • (Clermont-Ferrand laboratory)

  • FEE thresholds set at 10 mV

    • efficiency
  • the shape of each signal is sampled each ns to study amplitude, timing and released charge:

    • streamer comtamination


beam test setup (CERN: GIF + SPS-X5)



beam test: results (I)

  • 4 efficiency calculation methods:

    • Coincidence Register
    • tracking with DWC
      • total
      • core (higher beam irradiation rate)
      • outer circle (lower beam irradiation rate)
  • T/p correction:

  • HVeff=HV0*(T/T0)*(p0/p)

  • with T0=293.15 K, p0=970 mbar



beam test: results (II)



beam test: gas analysis

  • during the test  analysis of the exhaust gas were performed both for streamer and maxi-avalanche operation of the RPC



ageing test setup (CERN GIF)



small prototype 1: ageing results



gas mixture modification

  • we decrease the SF6 percentage to lower the working point

  • beam test on 2 small prototypes (50x50 cm2) to check the performances with the gas mixture:

  • 89.7% C2H2F4, 10% C4H10 + 0.3% SF6 – RH=50%

  • to make a direct comparison with the gas mixture with 2% SF6:

    • performances:
      • cluster size: 1.8 (1 cm strip)
      • time resolution: 1-2 ns
      • efficiency: in all position the efficiency plateau reaches 95-96%
      • no significant differences with respect to the gas mixture with 2% SF6
    • working HV~10000-10100 V (800 V lower)
      • streamer contamination <20%


small prototype 2: results



small prototype 3: results



efficiency plateaux



conclusions





Muon Trigger System



outline

  • beam test (X5-SPS) on a pre-production RPC:

    • RPC1, 70x270 cm2
    • efficiency¤t, cluster size and gas analysis
  • ageing test (GIF):

    • RPC 50x50 cm2 (small prototype 1)
  • beam test (X5-SPS)

    • 2 RPC 50x50 cm2 (small prototype 2&3)
  • ageing test (GIF):

    • 2 RPC 50x50 cm2 (small prototype 2&3)






Signal amplitude with cosmics II



Signal amplitude with cosmics III





beam test, setup - FEE



instability problem (I)



instability problem (II)



streamer contamination

  • % of streamer in the 25 tested positions at 3 different HVeff

  • (10000 V, 10100 V and 10200 V)

  • obtained with thresholds setting:

  • X plane: 8 mV

  • Y plane: 80 mV

  • the distributions of these values are shown in next slide



streamer contamination distribution