Organisation internationale de normalisation


Core experiments in SCC (21) CE1: Palette mode improvements (14)



Yüklə 5,54 Mb.
səhifə107/197
tarix02.01.2022
ölçüsü5,54 Mb.
#32757
1   ...   103   104   105   106   107   108   109   110   ...   197

Core experiments in SCC (21)

  1. CE1: Palette mode improvements (14)


(Consideration of this topic was chaired by GJS and JRO on Friday 06-19, 11:00-13:00 and by GJS 14:30-15:30.)
      1. CE1 summary and general discussion (1)


1.1.1.1.1.1.1.1.37JCTVC-U0021 CE1: Summary report of CE on palette mode improvement [P. Lai, V. Seregin, X. Xiu, C. Gisquet (CE coordinators)]

CE1 Test B proposed to remove condition checks for index adjustment. In this contribution, 3 different options were tested. In Test 1, index adjustment was removed when previous pixel has COPY_ABOVE mode. In Test 2, index adjustment was removed when previous pixel has COPY_INDEX mode. Test 3 removes index adjustment for both cases. Since Test 1 and Test 2 limit index adjustment based on previously decoded run_type, run_type should be signalled before grouped indices are signalled. Test 1 shows average 0.1%, 0.0%, 0.0% loss under AI, RA and LB configuration respectively. Test 2 shows average 0.3%, 0.2%, 0.2% loss under AI, RA and LB configuration respectively. Test 3.1 which doesnot signal run_type before grouped indices shows average 0.3%, 0.1%, 0.1% loss under AI, RA and LB configuration respectively and Test 3.2 which signals run_type before grouped indices shows maximum 0.3%, 0.2%, 0.1% loss under AI, RA and LB configuration, respectively.




Yüklə 5,54 Mb.

Dostları ilə paylaş:
1   ...   103   104   105   106   107   108   109   110   ...   197




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©muhaz.org 2024
rəhbərliyinə müraciət

gir | qeydiyyatdan keç
    Ana səhifə


yükləyin