3.2Draft text specification improvements [the right place for this?] 4.1.1Summary
JCTVC-J0021 CE1: Summary report of Core Experiment on intra transform mode dependency simplifications [K. Ugur, A. Saxena (CE coordinators)]
Three non-CE contributions were also noted to be relevant. These are listed in section 5.17.
In this core experiment, two simplifications were tested. Simplification 1 uses 2D DST for all intra prediction modes of 4x4 luma TUs rather than using mixed transform types (4 difference cases). Simplification 2 uses DST for all intra prediction modes of 4x4 luma TUs except that the DC mode is coded with DCT. Both simplifications show coding efficiency loss ranging between 0.0–0.1% on average excluding class F. In class F there was some more loss – between 0.2‒0.8% on average.
Visual testing was planned to be done for simplification 1 only.
It is intended to do visual testing
The results of visual testing were as follows:
(A BoG report about the tests will be was provided.).
Decision: Adopt simplification 1
Due to this adoption, there was no need to discuss the remaining documents under CE1
Dostları ilə paylaş: |