001060010 Insta contactor, 2 NO, Uc 230 V, Ue 250 V, Ie 20 A, for AC actuation
For AC continuous operation, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC, rated operational voltage 250 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 20 A, AC-1/AC-7a/NC contacts 20 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 9 A, rated power loss: Pick-up power 8 VA - holding power 3.2 VA - per contact AC-1/AC-7a, make/break times, less than 12 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 10 units/pole, parallel compensated 4 units/pole, DUO circuit 2 x 10 units/pole, with switch position indication, conductor cross-sections up to 4 mm2, 1 MW. Manufacturer/Type: Siemens/5TT57000
or similar
001060020 Insta contactor, 2 NO, Uc 24 V, Ue 250 V, Ie 20 A, for AC actuation
For AC continuous operation, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC, rated operational voltage 250 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 20 A, AC-1/AC-7a/NC contacts 20 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 9 A, rated power loss: Pick-up power 8 VA - holding power 3.2 VA - per contact AC-1/AC-7a, make/break times, less than 12 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 10 units/pole, parallel compensated 4 units/pole, DUO circuit 2 x 10 units/pole, with switch position indication, conductor cross-sections up to 4 mm2, 1 MW. Manufacturer/Type: Siemens/5TT57002
or similar
001060030 Insta contactor, 1 NO+1NC, Uc 230V, Ue 250V, Ie 20 A, for AC actuation
For AC continuous operation, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC, rated operational voltage 250 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 20 A, AC-1/AC-7a/NC contacts 20 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 9 A, rated power loss: Pick-up power 8 VA - holding power 3.2 VA - per contact AC-1/AC-7a, make/break times, less than 12 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 10 units/pole, parallel compensated 4 units/pole, DUO circuit 2 x 10 units/pole, with switch position indication, conductor cross-sections up to 4 mm2, 1 MW. Manufacturer/Type: Siemens/5TT57010
or similar
001060040 Insta contactor, 2 NO+1NC, Uc 24V, Ue 250V, Ie 20 A, for AC actuation
For AC continuous operation, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC, rated operational voltage 250 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 20 A, AC-1/AC-7a/NC contacts 20 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 9 A, rated power loss: Pick-up power 8 VA - holding power 3.2 VA - per contact AC-1/AC-7a, make/break times, less than 12 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 10 units/pole, parallel compensated 4 units/pole, DUO circuit 2 x 10 units/pole, with switch position indication, conductor cross-sections up to 4 mm2, 1 MW. Manufacturer/Type: Siemens/5TT57012
or similar
001060050 Insta contactor, 2 NC, Uc 230 V, Ue 250 V, Ie 20 A, for AC actuation
For AC continuous operation, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC, rated operational voltage 250 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 20 A, AC-1/AC-7a/NC contacts 20 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 9 A, rated power loss: Pick-up power 8 VA - holding power 3.2 VA - per contact AC-1/AC-7a, make/break times, less than 12 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 10 units/pole, parallel compensated 4 units/pole, DUO circuit 2 x 10 units/pole, with switch position indication, conductor cross-sections up to 4 mm2, 1 MW. Manufacturer/Type: Siemens/5TT57020
or similar
001060060 Insta contactor, 2 NC, Uc 24 V, Ue 250 V, Ie 20 A, for AC actuation
For AC continuous operation, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC, rated operational voltage 250 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 20 A, AC-1/AC-7a/NC contacts 20 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 9 A, rated power loss: Pick-up power 8 VA - holding power 3.2 VA - per contact AC-1/AC-7a, make/break times, less than 12 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 10 units/pole, parallel compensated 4 units/pole, DUO circuit 2 x 10 units/pole, with switch position indication, conductor cross-sections up to 4 mm2, 1 MW. Manufacturer/Type: Siemens/5TT57022
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 24 A, AC-1/AC-7a/NC contacts 24 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 6 A, rated power loss: Pick-up power 4 VA - holding power 4 VA - per contact AC-1/AC-7a 1.5 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 12 units/pole, parallel compensated 5 units/pole, DUO circuit 2 x 12 units/pole, with switch position indication, conductor cross-sections up to 10 mm2 rigid main connection, 2 MW. Manufacturer/Type: Siemens/5TT57300
Rated operational current: AC-1/AC-7a/NO contacts 24 A, AC-1/AC-7a/NC contacts 24 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 6 A, rated power loss: Pick-up power 4 VA - holding power 4 VA - per contact AC-1/AC-7a 1.5 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 12 units/pole, parallel compensated 5 units/pole, DUO circuit 2 x 12 units/pole, with switch position indication, conductor cross-sections up to 10 mm2 rigid main connection, 2 MW. Manufacturer/Type: Siemens/5TT57301
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 115 V AC 110 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 24 A, AC-1/AC-7a/NC contacts 24 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 6 A, rated power loss: Pick-up power 4 VA - holding power 4 VA - per contact AC-1/AC-7a 1.5 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 12 units/pole, parallel compensated 5 units/pole, DUO circuit 2 x 12 units/pole, with switch position indication, conductor cross-sections up to 10 mm2 rigid main connection, 2 MW. Manufacturer/Type: Siemens/5TT57302
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 24 A, AC-1/AC-7a/NC contacts 24 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 6 A, rated power loss: Pick-up power 4 VA - holding power 4 VA - per contact AC-1/AC-7a 1.5 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 12 units/pole, parallel compensated 5 units/pole, DUO circuit 2 x 12 units/pole, with switch position indication, conductor cross-sections up to 10 mm2 rigid main connection, 2 MW. Manufacturer/Type: Siemens/5TT57310
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC 24 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 24 A, AC-1/AC-7a/NC contacts 24 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 6 A, rated power loss: Pick-up power 4 VA - holding power 4 VA - per contact AC-1/AC-7a 1.5 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 12 units/pole, parallel compensated 5 units/pole, DUO circuit 2 x 12 units/pole, with switch position indication, conductor cross-sections up to 10 mm2 rigid main connection, 2 MW. Manufacturer/Type: Siemens/5TT57312
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 24 A, AC-1/AC-7a/NC contacts 24 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 6 A, rated power loss: Pick-up power 4 VA - holding power 4 VA - per contact AC-1/AC-7a 1.5 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 12 units/pole, parallel compensated 5 units/pole, DUO circuit 2 x 12 units/pole, with switch position indication, conductor cross-sections up to 10 mm2 rigid main connection, 2 MW. Manufacturer/Type: Siemens/5TT57320
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC 24 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 24 A, AC-1/AC-7a/NC contacts 24 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 6 A, rated power loss: Pick-up power 4 VA - holding power 4 VA - per contact AC-1/AC-7a 1.5 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 12 units/pole, parallel compensated 5 units/pole, DUO circuit 2 x 12 units/pole, with switch position indication, conductor cross-sections up to 10 mm2 rigid main connection, 2 MW. Manufacturer/Type: Siemens/5TT57322
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 24 A, AC-1/AC-7a/NC contacts 24 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 6 A, rated power loss: Pick-up power 4 VA - holding power 4 VA - per contact AC-1/AC-7a 1.5 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 12 units/pole, parallel compensated 5 units/pole, DUO circuit 2 x 12 units/pole, with switch position indication, conductor cross-sections up to 10 mm2 rigid main connection, 2 MW. Manufacturer/Type: Siemens/5TT57330
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC 24 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 24 A, AC-1/AC-7a/NC contacts 24 A, AC-3/AC-7b/NO contacts 9 A, AC-3/AC-7b/NC contacts 6 A, rated power loss: Pick-up power 4 VA - holding power 4 VA - per contact AC-1/AC-7a 1.5 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 100 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 12 units/pole, parallel compensated 5 units/pole, DUO circuit 2 x 12 units/pole, with switch position indication, conductor cross-sections up to 10 mm2 rigid main connection, 2 MW. Manufacturer/Type: Siemens/5TT57332
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 40 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 22 A, rated power loss: Pick-up power 5 VA - holding power 5 VA - per contact AC-1/AC-7a 3 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 40 units/pole, parallel compensated 10 units/pole, DUO circuit 2 x 40 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57400
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC / 24 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 40 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 22 A, rated power loss: Pick-up power 5 VA - holding power 5 VA - per contact AC-1/AC-7a 3 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 40 units/pole, parallel compensated 10 units/pole, DUO circuit 2 x 40 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57402
For AC or DC continuous operation, with DC solenoid system, NC contact Ie 30 A, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 40 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 22 A, rated power loss: Pick-up power 5 VA - holding power 5 VA - per contact AC-1/AC-7a 3 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 40 units/pole, parallel compensated 10 units/pole, DUO circuit 2 x 40 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57410
For AC or DC continuous operation, with DC solenoid system, NC contact Ie 30 A, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC / 24 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 40 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 22 A, rated power loss: Pick-up power 5 VA - holding power 5 VA - per contact AC-1/AC-7a 3 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 40 units/pole, parallel compensated 10 units/pole, DUO circuit 2 x 40 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57412
For AC or DC continuous operation, with DC solenoid system, NC contact Ie 30 A, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 40 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 22 A, rated power loss: Pick-up power 5 VA - holding power 5 VA - per contact AC-1/AC-7a 3 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 40 units/pole, parallel compensated 10 units/pole, DUO circuit 2 x 40 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57420
For AC or DC continuous operation, with DC solenoid system, NC contact Ie 30 A, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC / 24 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 40 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 22 A, rated power loss: Pick-up power 5 VA - holding power 5 VA - per contact AC-1/AC-7a 3 VA, make/break times, less than 40 ms, rated impulse withstand voltage: less than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 40 units/pole, parallel compensated 10 units/pole, DUO circuit 2 x 40 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57422
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 63 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 30 A, rated power loss: Pick-up power 6.5 VA - holding power 4.2 VA - per contact AC-1/AC-7a 6 VA, make/break times, less than 40 ms, rated impulse withstand voltage: higher than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 60 units/pole, parallel compensated 43 units/pole, DUO circuit 2 x 60 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57500
For AC or DC continuous operation, with DC solenoid system, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC 24 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 63 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 30 A, rated power loss: Pick-up power 6.5 VA - holding power 4.2 VA - per contact AC-1/AC-7a 6 VA, make/break times, less than 40 ms, rated impulse withstand voltage: higher than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 60 units/pole, parallel compensated 43 units/pole, DUO circuit 2 x 60 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57502
For AC or DC continuous operation, with DC solenoid system, NC contacts Ie 30 A, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 63 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 30 A, rated power loss: Pick-up power 6.5 VA - holding power 4.2 VA - per contact AC-1/AC-7a 6 VA, make/break times, less than 40 ms, rated impulse withstand voltage: higher than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 60 units/pole, parallel compensated 43 units/pole, DUO circuit 2 x 60 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57510
For AC or DC continuous operation, with DC solenoid system, NC contacts Ie 30 A, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC 24 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 63 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 30 A, rated power loss: Pick-up power 6.5 VA - holding power 4.2 VA - per contact AC-1/AC-7a 6 VA, make/break times, less than 40 ms, rated impulse withstand voltage: higher than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 60 units/pole, parallel compensated 43 units/pole, DUO circuit 2 x 60 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57512
For AC or DC continuous operation, with DC solenoid system, NC contacts Ie 30 A, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 230 V AC 220 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 63 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 30 A, rated power loss: Pick-up power 6.5 VA - holding power 4.2 VA - per contact AC-1/AC-7a 6 VA, make/break times, less than 40 ms, rated impulse withstand voltage: higher than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 60 units/pole, parallel compensated 43 units/pole, DUO circuit 2 x 60 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57520
For AC or DC continuous operation, with DC solenoid system, NC contacts Ie 30 A, according to EN 60947-4-1, EN 60947-5-1, EN 61095, rated control supply voltage 24 V AC 24 V DC, rated operational voltage 440 V AC 50/60 Hz, rated operational current: AC-1/AC-7a/NO contacts 63 A, AC-1/AC-7a/NC contacts 30 A, AC-3/AC-7b/NO contacts 30 A, rated power loss: Pick-up power 6.5 VA - holding power 4.2 VA - per contact AC-1/AC-7a 6 VA, make/break times, less than 40 ms, rated impulse withstand voltage: higher than 4 kV, electrical service life: 50 000 operating cycles, permissible ambient temperatures during operation: -25 to +55 °C, degree of protection: IP 20, incandescent lamp load 1000 W/pole, fluorescent lamp load 58 W: uncompensated 60 units/pole, parallel compensated 43 units/pole, DUO circuit 2 x 60 units/pole, with switch position indication, conductor cross-sections up to 25 mm2 rigid main connection, 3 MW. Manufacturer/Type: Siemens/5TT57522
For mounting on the left hand side of the 24 A, 40 A and 63 A Insta contactors, max. one auxiliary switch per Insta contactor, minimum contact load: 24 V AC 5 mA Manufacturer/Type: Siemens/5TT5900
or similar
001060290 Auxiliary switch, 1 NO + 1 NC , 230 V, 4 A, MW 0.5
For mounting on the left hand side of the 24 A, 40 A and 63 A Insta contactors, max. one auxiliary switch per Insta contactor, minimum contact load: 24 V AC 5 mA Manufacturer/Type: Siemens/5TT5901
or similar
001060300 Sealable terminal cover for Insta contactor 24 A, 2 MW
One set = 2 units Manufacturer/Type: Siemens/5TT5902
or similar
001060310 Sealable terminal cover for Insta contactor 40 - 63 A
One set = 2 units Manufacturer/Type: Siemens/5TT5903
or similar
001060320 Spacer, design for modular devices with 70 mm mounting depth