Part of the solution was to re-design the %VMXGSUM macro
so that it protects for possible missing variables in the
MIN, MAX, SUM, etc. operations done by %VMXGSUM, because
that should have been the original implementation. That
enhancement to %VMXGSUM is implemented herein in the 1st
part of this change.
Additionally, however, MXG 7.7 reports expected several
character variables that did not exist in MXG 6.6-built
PDBs. The second part of this change added statements to
supress the UNINITIALIZED VARIABLE messages if a cross-
version report (7.7 report from 6.6 data) is requested!
1.These sixteen new lines are inserted in member VMXGSUM:
After 025910 (IF DATETIME=. THEN DATETIME=.;) and before
026000 (&INCODE) insert:
%DO I = 1 %TO &NUMMAX %BY 1; 02592000
%LET VAR = %SCAN(&MAX,&I); 02593000
IF &VAR = . THEN &VAR = .; 02594000
%END; 02595000
%DO I = 1 %TO &NUMMIN %BY 1; 02596000
%LET VAR = %SCAN(&MIN,&I); 02597000
IF &VAR = . THEN &VAR = .; 02598000
%END; 02599000
%DO I = 1 %TO &NUMMEAN%BY 1; 02599100
%LET VAR = %SCAN(&MEAN,&I); 02599200
IF &VAR = . THEN &VAR = .; 02599300
%END; 02599400
%DO I = 1 %TO &NUMSUM %BY 1; 02599500
%LET VAR = %SCAN(&SUM,&I); 02599600
IF &VAR = . THEN &VAR = .; 02599700
%END; 02599800
2.If you MUST create new ANALDB2R MXG 7.7 reports from old
MXG 6.6-built PDB libraries, you must make these changes.
a.In two places in ANALDB2R, after lines 084860 and 110130
(each is: IF QWHSLOCN = ' ' THEN QWHSLOCN = ' ';),
replicate each line twice, then change the QWHSLOCN to
QLSTLOCN in the first replicate, then change the QWHSLOCN
to QLACLOCN in the second replicate.
b.Replicate line 006330 and change QWHSLOCN to QLACLOCN.
c.Change lines 015610 and 015620 (which initialize variable
QWHSDBAT and QWHSLOCN to four blanks) to now read:
IF QWHSDBAT=' ' THEN QWHSDBAT=' ';
IF QWHSLOCN=' ' THEN QWHSLOCN=' ':
d.Now, replicate this changed line 015620 thirteen times,
and change the replicated lines to now read:
IF QWHSLOCN=' ' THEN QWHSLOCN=' '; 015620
IF QLACLOCN=' ' THEN QLACLOCN=' '; 015621
IF QTXASELM=' ' THEN QTXASELM=' '; 015622
IF QTXASALM=' ' THEN QTXASALM=' '; 015623
IF QTXASPLM=' ' THEN QTXASPLM=' '; 015624
IF QTXABLLM=' ' THEN QTXABLLM=' '; 015625
IF QTXAINLM=' ' THEN QTXAINLM=' '; 015626
IF QTXAIOLM=' ' THEN QTXAIOLM=' '; 015627
IF QLACTRNS=. THEN QLACTRNS=.; 015628
IF QLACCNVQ=. THEN QLACCNVQ=.; 015629
IF QLACMSGS=. THEN QLACMSGS=.; 015630
IF QLACMSGR=. THEN QLACMSGR=.; 015631
IF QLACBYTS=. THEN QLACBYTS=.; 015632
IF QLACBYTR=. THEN QLACBYTR=.; 015633
Thanks to Dale St. Amant, Tenneco, USA.
Change 08.020 As discussed in Change 7.139 in MXG 7.7 CHANGES, SYNCSORT
VMACSYNC creates an invalid CPUTCBTM value (hex'555555'=15:32HHMM)
Mar 23, 1990 but it was not known why. SYNCSORT Early Warning Nr. 2803
now identifies the culprit; the use of FREE=CLOSE on the
SORTIN DDNAME causes SYNCSORT and MVS to both have issued
active STIMERS, which causes the corruption in their CPU
TCB time measurement. Eventually, SYNCSORT will fix the
conflict by zeroing out the field when a second STIMER is
set. MXG now recognizes '00555555'X and sets CPUTCBTM to
be missing in VMACSYNC. When the SYNCSORT fix is applied
in the future, a zero value instead of missing value will
result. This is a price you pay for FREE=CLOSE. Note that
even DFSORT specifically states to not specify FREE=CLOSE
on SORTIN DD statement
Note that this STIMER conflict ONLY affects the CPU time
that is measured by the 2nd STIMER issuer. The true CPU
TCB time in the SMF type 30 and the RMF type 72 records
are NOT affected, and remains correct.
Note also that FREE=CLOSE similarly affects SAS reported
CPU times on the SAS log, and can actually cause SAS to
ABEND with an internal apparent CPU TIME EXCEEDED error,
that also does not affect type 30/72 data, as was first
discussed on page 6 of MXG Newsletter TEN. With SAS, you
can still use FREE=CLOSE by specifying the NOSTIMER
option, which supresses CPU capture by not even issuing
the STIMER macro. (While SYNCSORT also has a NOSTIMER
option, it does not work in the same way, and will not
zero the CPU field when FREE=CLOSE is used.)
Thanks to Sam Sheinfeld, Kraft General Foods, USA.
Thanks to Nanette, SYNCSORT, USA.
Change 08.019 As documented in Newsletter SIXTEEN, MXG support for
VMACEPIL Candle's EPILOG/CICS was incomplete. It was also wrong!
XMACEPIL 1.The correct member to include (in member TYPEEPIL) is
XXACEPIL XMACEPIL in place of VMACEPIL, and DO NOT use XXACEPIL).
Mar 23, 1990 2.In member XMACEPIL, a + sign is missing in line 039300,
which should read: @121+OFFEPIL BISTIME ....
3.Variable WID should be 8 bytes (it is UOWID), but the
DEFAULT=4 causes it to be kept as only 4 bytes. It needs
to be added with explicit length 8, but eventually will
be converted and decoded into UOWID and UOWTIME.
Thanks to ???, ???.
Updated Jan 14, 1991. Member XMACEPIL was corrected and
copied into (replacing) member VMACEPIL, and then the
member XMACEPIL was deleted. All future EPILOG CL1000
support will be in member VMACEPIL, as it should have
been all along. See Change 8.212.
Change 08.018 System Managed Storage (SMS) now uses formerly reserved
VMXGVTOC bits located at offset '4E'x in the DSCB1 in your VTOCs.
Mar 22, 1990 DASD products like DMS/OS and ASM2 have used these bits,
and local modifications (to CSECTS IFG0196W and IFG0194E)
have also caused this "DSCB Contamination".IBM published
"Clean up VTOCs Before Implementing DFP V3"(as WSC Flash
9009, Hone Entry G022345) to advise you of the exposure.
If DSCB contamination is found, you must not only clean
the VTOCs of your online data sets, but you will need to
also clean all migrated datasets, since their DSCBs were
also migrated and your migration software will need to
correct the contamination when datasets are recalled.
The change in 8.2 creates these new SMS variables in the
VTOCLIST (for VMXGVTOR) or LIST (for VMXGVTOC) dataset:
DS1CRSDB='DADSM CREATE ORIGINATED BLOCKSIZE?'
DS1PDSE ='PDSE MANAGED DATASET?'
DS1REBLK='DATA SET MAY BE REBLOCKED?'
DS1SCAVB='SECONDARY IS ORIG AVG BLOCK LENGTH?'
DS1SCCP1='SECONDARY IS COMPACTED BY FACTOR OF 256?'
DS1SCCP2='SECONDARY IS COMPACTED BY FACTOR OF 65536?'
DS1SCKB ='SECONDARY IS IN KILOBYTES?'
DS1SCMB ='SECONDARY IS IN MEGABYTES?'
DS1SCUB ='SECONDARY IS IN BYTES?'
DS1SCXTV='SECONDARY SPACE EXTENSION VALUE'
DS1SMSDS='SYSTEM*MANAGED*DATASET?'
DS1SMSUC='NO BCS ENTRY EXIST FOR DATA SET?'
OFFSET4E='OFFSET 4E*INTO DSCB1*(USED BY SMS)'
2.The PROC SORT DATA = EXTENT; BY VOLSER POINTER; was
inside the %DO group was relocated outside, just before
the %DO, since no values in EXTENT were changed; this
will speed up execution slightly.
3.Adding variable OFFSET4E to VMXGVTOC is simple: replace
line 045100 (now containing only +4 ), with this:
@84 OFFSET4E $CHAR4.
and add OFFSET4E to the KEEP list for the LIST dataset.
Then, you can execute the following MXG program under TSO
to read the VTOC of your favorite VOLSER to see if it
suffers from DSCB contamination at offset '4E'x:
ALLOC F(DISK) DA('any data set on chosen volume') SHR
SAS OPTIONS('NODMS MAUTOSOURCE SASAUTOS=SOURCLIB VTOC')
%VMXGVTOC(DISK=DISK); RUN;
DATA CONTAMIN; SET LIST;
IF OFFSET4E NE '00000000'X THEN OUTPUT;
(Dataset LIST is built directly by VMXGVTOC. If you
have implemented VMXGVTOR to graze your entire DASD
farm, the SET LIST; statement would be replaced with
SET &LIB..MXGVTOC which contains all LIST datasets.)
If dataset CONTAMIN has non-zero observation count, then
you either have DSCB contamination, or SMF has already
been installed at your site!
Thanks to Tuanhung Doanvo, Philip Morris, USA.
Thanks to Jim Gilbert, Texas Utilities, USA.
Change 08.017 Hiperbatch hit/miss stats were added by IBM to type 14/15
VMAC1415 and type 64 by TNL (GN28-1284) dated Jan 3, 1990 that was
Mar 22, 1990 delivered today. (Had it been received even by Feb 20, it
would have been implemented in MXG 7.7, avoiding this
change!). The change adds five new fields to both the
TYPE1415 and TYPE64 data sets. While the fields are the
same, IBM used two different field names/acronyms:
TYPE1415 TYPE64 Description
name name
SMFIOREQ SMF64SIO Hiperbatch total searches/requests
SMFCHITS SMF64HIT Successful searches
SMFPHIOS SMF64MIS Misses; caused physical DASD I/O
SMFCIOS SMF64IOS Misses that were copied into buffers
SMFNMWTS SMF64WTS Suspends due to conflict other users
Change 08.016 TPX dataset TPXINTRV will have zero observations because
VMACTPX of mis-alignment in the subtype 2 or 4 records. After
Mar 22, 1990 line 040900 insert:
IF TPXVER GE 200 THEN INPUT TPX24LEN PIB2.
TPX24ID $CHAR2.
@;
Note: TPX24ID was printed in error as $CHAR4. in Newsletter
SEVENTEEN, but was correct in MXG PreRelease 8.2 and
later software. It should be $CHAR2. as shown above.
Thanks to Kari Strand, Televerkets EDB-tjeneste, NORWAY.
Thanks to Doug Mayward, Pharmaceutical Data Services, Inc, USA.
Change 08.015 New subtype 3 of the existing SMF type 41 record provides
EXTY41AC usage statistics of the Virtual Lookaside Facility (VLF).
EXTY41UN Interval records (15 min) are written for each class in
EXTY41VF your COFVLFnn member of PARMLIB that is currently in use.
VMAC41 MXG creates dataset TYPE41VF from this subtype, reporting
Mar 22, 1990 (for each VLF class used) the MAXVIRT size, the storage
used, counts when objects were found in, added to,
deleted from or trimmed from VLF during the interval,
the largest object attempted to be added to VLF since VLF
was started, and the VLF "pct found/hit ratio". Multiple
VLF classes (CSVLLA, IGGCAS, IKJEXEC) can exist in one
type 41 subtype 3 record; multiple observations with the
same SMFTIME will be created by MXG. This change deletes
the existing TYPE41 dataset built from subtypes 1 and 2
and in its place creates two: TYPE41AC (DIV Accesses)
and TYPE41UN (DIV Unaccesses), which now keep only the
variables specific to those DIV events.
Thanks to Dan Barbatti, Southwestern Bell, USA.
Thanks to Jim Gilbert, Texas Utilities, USA.
Change 08.014 These circumvention members (for SAS 344 compiler limit)
XMAC7072 did not keep ZDATE in all datasets and had a typographic
XMAC71 error.
Mar 22, 1990 1.In XMAC7072, add ZDATE to the KEEP list for TYPE70PR and
TYPE72MN datasets.
2.In XMAC71, remove the extraneous period before the final
semicolon in line 031800.
Thanks to Bruce Widlund, Texas Utilities, USA.
Change 08.013 DB2 data read from GTF did not have DATETIME21.2 format
VMACSMF nor LENGTH=8 for SMFTIME variable, but now _GTFDB2 macro
Mar 22, 1990 contains SMFTIME in both FORMAT and LENGTH statements.
Thanks to Susan Marshall, SAS Institute Europe, GERMANY.
Change 08.012 As noted in comments, type 79 support had not been tested
VMAC79 with real records. Now it has, and these changes will be
Mar 21, 1990 required to avoid STOPOVER or invalid data conditions.
1.These seven actions are SPF commands to be entered on the
command line while SPF EDITing member VMAC79 to make the
global changes (note that blanks ARE important):
a.EXCLUDE ALL
b.FIND ' = ' ALL (16 occurrences found)
c.CHANGE ' = ' '=' ALL
d.CHANGE ' BY ' '-1 BY ' ALL NX
e.EXCLUDE ALL
f.FIND ' LE LENGTH' ALL (21 occurrences found)
g.CHANGE ' LE LENGTH' '-1 LE LENGTH' ALL
2.Change line 013800 to read CYCLE ?? PD4.
3.Insert new line 015910 (after 105900) R79LF2 $CHAR1.
4.Change line 016200 to read R79RSV $CHAR2.
5.Change line 016900 to read R79IST ?? PDTIME4.
6.Change three occurrences in two lines of R792SLQR to read
R792LSQR.
7.These first six items bring the code up for MVS/ESA, but
for MVS/XA, other STOPOVER conditions are guaranteed, as
the code was only written for ESA. Guess what, though.
A real slick trick for MVS/XA execution (pointed out to
me by a user who got the trick from LEGENT's MICS) is to
execute with this code:
MACRO STOPOVER MISSOVER %
%INCLUDE SOURCLIB(TYPE79);
which will simply set the non-MVS/XA variables missing!
(I seldom use MISSOVER, because it does not tell you
that there were short records; I need STOPOVER so that
I GET the dump of the record, but is perfect here.)
Eventually, I may retrograde the code to support the XA
records, by breaking up the INPUT statement and inputting
conditionally the MVS/ESA variables, and thereby support
both MVS/XA and MVS/ESA type 79 data records, if that is
really necesary!
Thanks to Ron Thein, Mortgage Guaranty Insurance Corp., USA.
Thanks to Dan Barbatti, Southwestern Bell, USA.
Thanks to Randy Catlin, CENTEL.
Change 08.011 New member ZZZZZZZZ now exists as the last member of the
ZZZZZZZZ MXG library (AAAAAAAA is the first) so that it will be
Mar 15, 1990 easy to verify that all of the MXG Source Library ("from
AAAAAAAA to ZZZZZZZZ") has been successfully unloaded.
(Twenty new customers received incomplete MXG 7.7 tapes
from SAS before a customer discovered that only 1057 of
the 1100 members had been copied from our master tape!)
Thanks to Don Ehrig, Pearl Vision, USA.
Change 08.010 Support for NETSPY 3.2 was incomplete. NSPYVIRT (Virtual
VMACNSPY Route) variables APACING HOSTSUB OSTAGEP VRBLOCKD VRHELD
Mar 15, 1990 VRBHELDT VRBNSESS VROPEN VRBOPACT VRBPRTME were not input
and APPLID was replaced by SUBHOST. NSPYLINE variables
NSPDLY NSPDIALU NSPNMAXD NAPNMAXO NSPNANC NSPNCA NSPNNELS
NSPNPACE NSPNPLIM NSPNRTO NSPNSLIM were not input. These
un-input variables did not cause MXG to fail, they just
were not read in. Three other variables were actually
wrong and must be changes.
1.Line 052500 should read: BUF_UTIL=100 - FBLPCT;
so that minimum free buffers are used to calculate buffer
utilization (instead of average free buffers).
2.Line 059400 should read: COTPUTSZ PIB8.
(as PIB4., COTPUTSZ, Output Length, was always zero).
3.Move NETWADDR in line 009400 (in data set NSPYLU keep) to
line 008000 (in data set NSPYLINE keep list).
Thanks to Marty Quinlan, Virginia Power, USA."
for extensive validation.
Change 08.009 The %VMXGVTOR macro which invokes the FMXGUCBL function
FMXGUCBL was not correct. Changes made in VMXGVTOC (which is the
VMXGVTOR piece that actually reads the VTOC) were not propagated.
Mar 15, 1990 1.In member VMXGVTOR:
Jun 13, 1990 a. In lines 002200 and 002300 replace &I with &IVTOR.
b. Replace two lines 002500 and 002600 with these three:
PROC APPEND BASE=&LIB..VTOCLIST NEW=LIST FORCE;
PROC APPEND BASE=&LIB..VTOCMAP NEW=MAP FORCE;
PROC APPEND BASE=&LIB..VTOCINFO NEW=INFO FORCE;
2.The FMXGUCBL function was modified in MXG 7.7 (see page
17 of MXG Newsletter SIXTEEN), so the function would work
compatibly under either SAS 5.18 or SAS 6.06+, but it was
only tested under SAS 6.06! Under SAS 5.18, the MXG 7.7
FMXGUCBL returns a value too large by one. The following
change DOES work under either version of SAS and does let
a single assembly of this function to work witheither
SAS 5.18 or 6.06+. Change member FMXGUCBL lines 017400
thru 017500 so they now read:
MVC WORKAREA(4),=XL4'4E000000' 01740000 no change
LD FR0,WORKAREA 01741000 was SD FR0,FR0
XC WORKAREA+4(4),WORKAREA+4 01742000 new line
AD FR0,WORKAREA 01750000 no change
Thanks to Jeff Fox, SKF Inc, USA.
Thanks to David Fahey, SAS Institute Cary, USA.
Change 08.008 This is a complete revision of the text of this change
IMACVMON that was published in MXG Newsletter SEVENTEEN.
VMACVMON 1.The Q1SEC equation was wrong. The actual calculation
Jul 19, 1990 is Q1SEC=SUM(Q1TIME,E1TIME)/SUM(Q1DROPS,Q1); .
The lines affected by this change are:
a. After 035700, insert Q1SEC (to the KEEP= list)
b. After 082100, insert Q1SEC='AVERAGE*Q1SEC*DURATION'
c. After 146800, insert two lines:
DENOM=SUM(Q1DROPS,Q1);
IF DENOM GT 0 THEN Q1SEC=SUM(Q1TIME,E1TIME)/DENOM;
ELSE Q1SEC=.;
d. After 170000, insert Q1SEC (to the RETAIN list).
2.Comments in IMACVMON were added to stress the importance
of setting _INTRV macro value to equal your VM/Monitor
interval. If you leave the MXG default _INTRV value of
1 minute, but actually write records at 15 minutes, MXG
will throw away all USER and DASTAP data.
3.Variables PCTQUEDV/PCTQUECU were wrong, and instead of
containing the percentage of monitor intervals during
which there was a queue (as VM MAP calculates), these
MXG variables actually contained 100 times the average
number of entries in the queue. Now, they are correct and
should agree with VM MAP. The label for PCTQUEDV was
corrected and a label provided now for PCTQUECU.
4.The VM/370 SEEK (Class 7) reports in ANALVMDY do not work
and have not been fixed in MXG 8.7. It was re-packaged
incorrectly and causes syntax errors. Also, the logic to
match Seek address with the Mini-Disk directory may cause
ambiguous results, because it turns out that directory
entries can overlap. Pended for test data and test site.
Thanks to Bob Small, Grumman Data Systems, USA.
Thanks to George Ellard, Federal Express, USA.
Change 08.007 TSO/MON data set TSOMDSNS did not contain SYSTEM, and
TYPETSOM TSOMCMND had missing STRTTIME if there were enough users
Mar 19, 1990 logged on to create multiple System records for one
interval. (The TSOMSYST data set was protected by retain,
but the restore logic was after TSOMCMND was output.)
1.Add SYSTEM to keep list at line 005200.
2.Move three lines 084200 thru 084400 (which restore
STRTTIME,ENDTIME,and MAXUSERS from TSOMSTAR,TSOMENDT,and
TSOMAXUS) to immediately after line 072700 (before the
COMNDTYP='00'X; statement.
Thanks to Pete Shepard, Ashland Oil, USA.
Change 08.006 TYPEIMS IMS Log processing had missing values if IMS
TYPEIMS crashed repeatedly, due to duplicate DTOKEN values.
Mar 19, 1990 1.Move IMSTAPNO in lines 035400 and 035800 to make the line
read: BY IMSTAPNO DTOKEN PSTNUMBR TRANSACT IMSRECNO;
2.Insert IMSTAPNO in line 036900 to make the line read
BY IMSTAPNO DTOKEN;
3.Move IMSTAPNO in lines 094900 and 095300 to make the line
read: BY IMSTAPNO DTOKEN ARRVTIME GUTIME IMSRECNO;
4.Insert IMSTAPNO in line 108300 to make the line read
BY IMSTAPNO DTOKEN;
Thanks to Pete Shepard, Ashland Oil, USA.
Change 08.005 IDMS Performance Monitor SMF record variables PGMTYPE,
VMACIDMS TASPTYPE, and TASTTYPE were kept as 8-byte variables and
Mar 15, 1990 with $HEX2. format. They should have been 1-byte length
with the $MGIDMPP, $MGIDMTT, and $MGRTEPT formats. Also,
the IDMSDBK data set was never output.
1.Delete the semicolon at the end of the LENGTH statement
in line 072000, and insert this new line
PGMTYPE $1. TASPTYPE $1. TASTTYPE $1.;
to force their length to only one byte, and then also
2.Remove these same three variable names from line 072400
(where the $HEX2. format overrode line 072000).
3.Change line 154800 from EXIDMCDM to EXIDMDBK.
Thanks to Mike Eisenhart, York International, USA.
Thanks to Mark Robbins, Jaguar Cars, ENGLAND.
Change 08.004 Candle's OMEGAMON/VM for VM/XA has an option to reformat
VMACVMXA IBM's MONWRITE data records into a Variable Blocked (VB)
Mar 15, 1990 file. Unfortunately, their program did not create valid
VB format records. They incorrectly added an extra RDW
(Record Descriptor Word of 4 bytes) in front of the real
RDW (does this make the record a VVB format!).
Because VB records are easier to work with during testing
and because it was hoped that IBM would eventually change
MONWRITE to create legitimate VB data files, MXG's VM/XA
support defined the _OUTFILE macro, that does create true
VB data records from IBM's MONWRITE records, and MXG's
_VMINPUT macro was defined to process those (future!) VB
records. With only a minor change, MXG's _VMINPUT macro
can be modified by Candle sites to process those invalid
"VVB" format data. Candle has acknowledged their error,
and announced that a permanent solution (i.e., correct
VB record format) would be provided in their next release
of VCOLLECT in their Version 4.10, in second quarter 90.
Before 4.10, Candle sites can read the "VVB" data by the
followin new line inserted after 769000 (ends a PUT that
precedes the INPUT MRHDRDM ... ), skipping over the RDW:
INPUT +4 @;
BUT THIS CHANGE IS ONLY FOR CANDLE "VVB" PRIOR TO 4.10.
IT MUST BE BACKED OUT WHEN YOU INSTALL THEIR 4.10.
Candle's VCOLLECT Incident Number is 81696.
2.To read real VB data (either from Candle 4.10 or using
MXG's _OUTFILE), if you have installed the IBM PTFs that
are described in Change 7.219, you will need to add this
correction (unrelated to the Candle problem, but observed
while debugging the Candle-created problem):
The following line must be inserted after line 769600:
LENGTH=LENGTH+4;
(immediately before the MRHDRLEN=LENGTH; statement), to
set LENGTH to the physical instead of logical record
length, as expected by MXG's MONWRITE logic.
Thanks to Mark Flugrath, WVNET, USA.
Change 08.003 DASDMON data sets did not have SMFTIME and ZDATE in their
VMACDMON KEEP= list, causing uninitialized variable error in the
Feb 26, 1990 ANALDMON report program. Now they do.
Thanks to Danny High, Blue Cross Blue Shield Texas, USA.
Change 08.002 ACF2 ARE data segment had two bytes not read, causing a
VMACACF2 STOPOVER condition. If the ARE did not exist, a program
Feb 23, 1990 loop could occur.
Mar 22, 1990 1.Insert two new lines, after line 052000 and 054200 (both
of which are ACLFLDNM $CHAR8.). The new lines contain
+2
(thereby skipping over two bytes after ACLFLDNM).
2.Change line 051500 to now read:
IF ACLAFARE GT 0 AND ACLMFLGS NE '...1....'B THEN DO;
3.Change line 053700 to now read:
IF ACLBFARE GT 0 AND ACLMFLGS NE '..1.....'B THEN DO;
Thanks to Roman Gudz, Leaseway Transportation, USA.