Figure : Infusion process at APC (left), samples manufactured (middle) and delamination problems during the mechanical characterization (right)
The following table summarized the problems appeared during the scale-up and the solutions propose for the demonstrators manufacturing.
MANUFACTURING PROCESS
|
PROBLEM AT THE SCALE-UP STEP
|
SOLUTION PROPOSED FOR THE DEMONSTRATORS
|
APC: glass fibre reinforced furan composite
|
The use of biaxial glass fibre leads to delamination problems at industrial level.
|
Use of chopped strand mat and roving.
Not expected important changes in the reaction to fire properties due to the change of the fibre type (non combustible material).
|
AMORIN: cork agglomeration
|
Cork panels agglomerated with furan resins break because of internal pressure when pressing.
|
Use of standard not flame retarded cork panels in the final demonstrators.
|
5.-WP3 Summary. Inputs to WP6: proposed demonstrator lay out
As a final result of the WP3, a sandwich panel lay out was proposed for the final demonstrators (WP6) regarding railway and naval sectors. The lay-out is collected in Figure .
Depending on the final application the number and the thicknesses of internal cork cores and intermediate layers can vary (Figure ).
These demonstrators and their properties will be described in the corresponding work package report (WP6).
Figure : Lay out of the sandwich panel proposed to WP6
Figure : Demonstrators manufactured for rail (left) and maritime (right) sectors.
Dostları ilə paylaş: |