100 general provisions


TABLE 710.03-1M STEEL POSTS, GATE FRAMES, POST BRACES, AND TOP RAILS



Yüklə 7,65 Mb.
səhifə91/108
tarix18.01.2019
ölçüsü7,65 Mb.
#100759
1   ...   87   88   89   90   91   92   93   94   ...   108

TABLE 710.03-1M STEEL POSTS, GATE FRAMES, POST BRACES, AND TOP RAILS

Usage – nominal fence height 1.8 m or less

Section

Thickness



Outside Diameter or Dimensions

(mm)


Weight

Nominal


(kg/m)

Minimum

Tolerance

(%)


Yield

Strength


(MPa)

Line posts

Grade 1 Pipe

60

5.4

-5

178

Grade 2 Pipe

60

4.6

-5

348

C-Section

57  43

4.1

-6

310

H-Section

57  43

4.9

-5

310

End, corner pull posts

Grade 1 Pipe

73

8.6

-5

178

Grade 2 Pipe

73.00

6.9

-5

345

Square

64.00

8.5

-3

276

Roll-form

89  89

7.6

-6

241

Gate Posts, for nominal width of gate (single or one leaf of Double):

Up to 1.8 m incl

Grade 1 Pipe

73.00

8.6

-5

178

Grade 2 Pipe

73.00

6.9

-5

345

Square

64.00

8.5

-3

276

Roll-form

89  89

7.6

-6

241

Over 1.8 to 4 m incl.

Grade 1 Pipe

102.00

13.6

-5

178

Grade 2 Pipe

102.00

9.8

-5

345

Square

76.00

13.9

-3

276

Over 4 to 5.5 m incl.

Grade 1 Pipe

168.00

28.2

-5

178

Over 5.5 m

Round

219

36.8

-5

178

Gate frames

Grade 1 Pipe

48

4.0

-5

178




Grade 2 Pipe

48

3.4

-5

345




Square

51

4.0

-3

276

Top rails,[1]

post braces



Grade 1 Pipe

42

3.4

-5

175

Grade 2 Pipe

42

2.7

-5

345

H-Section

38  33

3.3

-5

310

Roll-form

41  32

2.0

-6

241

Round tubing

42

2.1

-5

345

[1] When tension wire is specified, it will be of 4.5 mm diameter.

Furnish ornamental cap post tops made of steel, malleable iron or cast iron. Furnish them with a hole suitable for through passage of the top rail. Ensure that they fit snugly to the post, have a means of attaching securely to the post, and exclude moisture from tubular posts. Furnish swing type gates complete with latches, stops, keepers, hinges, locks, and fabric. Cover them with fabric matching the fence. Furnish hinges of adequate strength to support the gate and that do not twist or turn under action of the gate. Locate plunger bar type latches at the full gate height in a manner that will engage the gate stop. Forked latches may be used for single gates less than 10 feet (3 m) wide. Furnish lockable latches. Furnish stops that consist of a flush plate with anchor placed in concrete to engage the plunger bar of the latch. Other approved types of stops may be used for single gates less than (10 feet) 3 m wide. Keepers are substantial devices for securing and supporting the free end of the gate in open position.

Furnish top rail couplings consisting of the outside sleeve type at least 6 inches (150 mm) long. Ensure that a minimum of 20 percent of the coupling has an internal heavy spring to take up expansion and contraction.

Furnish gate frames that are assembled by welding, using properly designed, formed sheet, or sandcast fittings. Cover the gates with fabric matching the fence.

Furnish offset type hinges. Furnish galvanized latches, stops, and keepers made of malleable iron, except for plunger bars that may be galvanized tubular or bar steel according to Section 6.2.

Furnish top rails in lengths not less than 18 feet (5.5 m).

Furnish flat stretcher bars in 3/4  1/4-inch (19  6 mm) sections.

Furnish self-centering outside rail couplings that are 6 inches (150 mm) long.

Furnish tie wire that has a 0.148-inch (3.7 mm) minimum diameter and that meets an aluminum alloy.

Furnish wrought or cast turnbuckles.

Furnish truss and brace rods with an 3/8-inch (9.5 mm) outside diameter or equivalent cross-section.

Furnish beveled brace bands in 1  1/8-inch (25  3 mm) section.

Furnish bolts with an anodic coating at least 2 mil (5 m) in thickness, chromate sealed.

11.1. Ensure that the size of the fabric conforms to 0.148-inch (3.7 mm) nominal diameter of coated wire, 2-inch (50 mm) mesh.

14.1 Table 8. Type I Zinc-Coated Steel Chain Link Fabric will have Class D weight of coating.

15.5 Ensure that the vinyl covering is of a uniform medium green color.

19.1 Perform inspection at the project site.

32.2 Does not apply.

32.3.3.2. Increase the minimum weight of interior coating to an average of 0.9 ounces per square foot (275 g/m2) and not less than 0.8 ounces per square foot (244 g/m2) on an individual specimen.

TABLE 710.03-2 DIAMETERS OR PLAIN END, SCHEDULE 40 ALUMINUM ALLOY PIPE

The weights and dimensions are as specified in ANSI H 35.2.






Nominal Pipe Size

Material

(in)

(mm)

Brace rails and top rails

1 1/4

32

Gate frames and rail couplings

1 1/2

40

Line posts

2

50

End and corner posts

2 1/2

65

Gate posts single or one leaf of double:







Gate opening




(ft)

(m)

(in)

(mm)

To 6

To 1.8

2 1/2

65

Over 6 to 12

Over 1.8 to 3.7

3 1/2

90

Over12 to 18

Over 3.7 to 5.5

6

150

Over 18 to 32

Over 5.5 to 9.8

8

200

A 8’8” line post may be substituted in lieu of the line post shown on standard drawings Chain Link Fence 1.1, 7-28-00 and Walk Gates F-3.2, 7-28-00. This will be accomplished by reducing the 4’-0” depth as necessary to accommodate the shorter posts, all other dimensions shown in the standard drawings shall remain unchanged

Furnish certified material according to Supplement 1067.

710.06 Deep Beam Rail. Furnish deep beam rail according to AASHTO M 180, Type II, Class A, with the following modifications:

5.1 Perform inspection at the project site.

5.2.1 When a field check of coating thickness shows insufficient coating thickness or shows insufficient coating weight, sample and test the guardrail.

9.1.2 The minimum check limits for both triple and single-spot tests apply.

Furnish certified material according to Supplement 1042.

710.09 Wire Rope Rail. Furnish wire rope rail according to AASHTO M 30, Class A, Type I rope, with the following modification:

9 Perform inspection at the project site.

Obtain random samples from material delivered to the project site or at other locations designated by the Laboratory.

710.11 Fence Posts and Braces. Furnish round wood posts conforming to 710.12 and 710.14. Furnish dimension timber, posts, and lumber for braces and stream crossings that are sound, straight, free from unsound or loose knots, splits and shakes, and that are treated according to 712.06.

Furnish steel line posts according to ASTM A 702, with the following modifications:

5.6.2 Furnish fasteners or clamps that have a 0.120-inch (3 mm) diameter and that are galvanized according to ASTM A 116, Type Z, Class 3.

5.6.1 Supply each post with a sufficient number of fasteners or clamps.

6.2 Ensure that the post lengths are as designated.

7.1 Furnish galvanized line posts and anchors according to 711.02.

7.2 Delete.

9. Perform sampling according to 712.06.

Furnish certified material according to Supplement 1067.

710.12 Square-Sawed and Round Guardrail Posts. Furnish pressure treated square-sawed and round guardrail posts according to 710.14 and 712.06. Cut posts from growing timbers that are free from unsound or loose knots and rot and from injurious or excessive shake, and season checks that exceed 1/4 inch (6 mm) in width.

Furnish round posts that are 8  1 inch (200  25 mm) in diameter and have a uniform taper. Ensure that the sweep does not exceed 1 inch (25 mm) for the length of the post. Peel round posts their entire length, removing all outer and inner bark and leather fiber by shaving the surface. Trim knots even with the post, and saw both ends of the post square.

Furnish square sawed posts that are free from injurious cross grain and sapwood. They may contain a limited number of sound knots that do not exceed 2 inches (50 mm) in diameter. Ensure that they are from wane above the ground line. Ensure that the wane below the ground line is limited to two adjacent corners and does not exceed 1 1/2 inches (38 mm) measured along the wane.

Furnish certified material according to Supplement 1072.



710.14 Pressure Treated Guardrail and Fence Posts, Braces, and Blocks. Furnish pressure treated guardrail and fence posts, braces, and blocks according to AASHTO M 168 and 710.11, 710.12, and 712.06.

Furnish certified material according to Supplements 1042 and 1072.



710.15 Steel Guardrail Posts. Furnish steel guardrail posts in the sections and lengths as specified. Ensure that they are made of copper bearing steel when so specified. Furnish steel according to ASTM A 36/A 36M. Furnish galvanized posts according to 711.02.

Furnish certified material according to Supplements 1042.



710.16 Guard Posts. Furnish pressure treated wood posts according to 710.14 Furnish posts that are either 5  6-inch (125  150 mm) sawed square or 5 1/2-inch + 1/2-inch (138 mm) diameter round when measured 30 inches (0.75 m) from the top. Furnish posts that are 5 feet, 3 inches (1.6 m) in length and are embedded such that 30 inches (0.75 m) remains exposed. Ensure that the center-to-center spacing is spaced at 6 feet (1.8 m) intervals, unless otherwise shown on the plans.

Furnish certified material according to Supplements 1042


711 STRUCTURAL STEEL AND STRUCTURE INCIDENTALS

711.01 Structural Steel. Furnish structural steel conforming to ASTM A 709, Grade 36 (A36), 50 (A572), 50W (A588), or 70W.

Ensure that materials designated to meet notch toughness requirements have a minimum longitudinal Charpy V-Notch (CVN) energy absorption value as listed below. Sample and test according to ASTM A 673/A 673M. Use the (H) frequency of heat testing and provide the test data as required by 501.06.



ASTM

Designation

Thickness and Connection Method

Value Min CVN

A709 Gr. 36 (A36, A36M)

Up to 4 in (102 mm) mechanically fastened or welded

15 ft-lb @ 40 F

(20 J @ 4 C)



A709 Gr. 50 (A 572/A 572M),

A709 Gr. 50W (A 588/A 588M)



Up to 4 in (102 mm) mechanically fastened

15 ft-lb @ 40 F[1]

(20 J @ 4 C)



A709 Gr. 50 (A 572/A 572M),

A709 Gr. 50W (A 588/A 588M)



Over 2 to 4 in (51 to 102 mm) welded

20 ft-lb @ 40 F[1]

(20 J @ 4 C)



A709 Gr. 50 (A 572/A 72M),

A709 Gr. 50W (A 588/A 588M)



Up to 2 in (51 mm) welded

15 ft-lb @ 40 F[1]

(20 J @ 4 C)



A709 Gr. 70W


Up to 4 in (100 mm) mechanically fastened or welded

2515 ft-lb @ -10 40 F[1]

(34 20 J @ -23 C)



[1] If the yield point of the material exceeds 65 ksi (448 MPa), the temperature of the CVN value for acceptability should be reduced by 15 F (8.3 C) for each increment, or part of increment, of 10 ksi (69 MPa) above 65 ksi (448 MPa).


711.02 Galvanized Steel. Furnish galvanize steel according to ASTM A 123 after cutting, bending, and welding. At the discretion of the Engineer, replace, re-galvanize, or repair damaged galvanized material. If a repair is authorized, use a method acceptable to the Engineer. Do not use galvanizing spray.

Furnish bolts, nuts, washers, and similar threaded fasteners that are galvanized according to ASTM A 153. These items may be mechanically zinc coated according to ASTM B 695, Class 50. Except for ASTM A 325 (ASTM A 325M) bolts, electrogalvanizing may also be used if the coated item meets the thickness coating requirements of ASTM A 153.



711.03 Steel for Piling. Furnish steel for H-piling conforming to ASTM A 572 Grade 50 / A 572M Grade 345. Furnish steel for sheet piling according to ASTM A 328/A 328M.

711.04 Cold Rolled Steel. Furnish cold rolled steel according to ASTM A 108, Grades 1016 through 1030 for pins, rollers, trunnions, and other similar parts.

711.07 Steel Castings. Furnish steel castings according to ASTM A 27/A 27M, Grade 65-35 or Grade 70-36, with the following modification:

Ensure that steel castings are free from pouring faults, sponginess, cracks, blow holes, and other defects in positions affecting their strength and value for the service intended. No sharp, unfilleted angles or corners are allowed.



711.08 Arc-Welding Electrodes and Fluxes. The following applies to all steel, except for exposed bare ASTM A 242/A 242M and ASTM A709 Grade 50W (A 588/A 588M) steels. For exposed bare ASTM A 242/A 242M and A709 Grade 50W (A 588/A 588M) applications, see Table 711.08-1.

A. Manual shielded metal-arc welding.

1. AWS A5.1 Low Hydrogen Only

2. AWS A5.5 Low Hydrogen Only

B. Submerged Arc Welding

1. AWS 5.175

2. AWS 5.235

C. Gas metal-arc welding, AWS A 5.185

D. Flux cored arc welding, AWS A5.205

Table 711.08-1

Filler metal requirements for exposed bare applications of

ASTM A 242/A 242M and ASTM A709 Grade 50W (A 588/A 588M) steel.


Welding Process

Shielded metal arc

Submerged arc[5]

Gas metal arc or Flux cored arc[2],[4], [5]

AWS A5.5

AWS A5.23

AWS A5.28 and 5.29

E8015, 8016, or 8018 electrodes that deposit weld metal meeting C1, C1L, C2, C2L, C3, or W analysis

All electrode-flux combinations that deposit weld metal with a Ni1, Ni2, Ni3, Ni4, or W analysis [2],[3]

All electrode-flux combinations that deposit weld metal with a Ni1, Ni2, Ni3, Ni4, or W analysis


[2] Deposited weld metal will have a minimum impact strength of CVN 20 ft-lb (27 J) at 0 F (-18 C) (only applied to bridges).

[3] The use of the same type filler metal having next higher mechanical properties as listed in AWS specification is permitted.

[4] Deposited weld metal will have a chemical composition the same as that for any one of the weld metals in this table for the shielded metal arc welding process.

[5] In conformance with those classifications allowed under AWS D1.5 Bridge Welding Code, Tables 4.1 and 4.2.


The Laboratory will issue a list of approved electrodes and combinations of shielding. The Laboratory will include electrodes in the list when certified test data submitted by the manufacturer is found in compliance with the specified requirements. The certification will cover either process qualification or quality control tests. To qualify, such tests must be made within one year before the period covered. For each submission of certified test data, include the manufacturer’s statement that it will advise the Laboratory immediately of any change in materials or processing used in the manufacture of the electrodes made within one year from the date of the tests.

When electrodes to be used are not included in the Laboratory’s list of approved electrodes and combinations of shielding, submit certified test data as described above for each lot showing compliance with the specified requirements.


Yüklə 7,65 Mb.

Dostları ilə paylaş:
1   ...   87   88   89   90   91   92   93   94   ...   108




Verilənlər bazası müəlliflik hüququ ilə müdafiə olunur ©muhaz.org 2024
rəhbərliyinə müraciət

gir | qeydiyyatdan keç
    Ana səhifə


yükləyin