R4-021613 BS IPDL requirement (Nortel Networks)
Tuomo Säynäjäkangas (Nokia) objected that the area of the cell for which the IPDL requirement should be set is precisely in the vicinity of the BS. Eric Georgeaux (Nortel) noted that it has been traditionally assumed in WG4, for ACLR and UE ACS for example, that the UE is not close to the BS.
It seems that no agreement can be reached. So far, companies have expressed the following preferences:
Nokia
|
- 45 dB
|
Ericsson
|
- 25 dB
|
Nortel
|
- 25 dB
|
Siemens
|
- 40 dB
|
Given the bottleneck situation, after a year of discussion on this topic the interested companies haven't been able to reach consensus, the chairman decided to go for a vote. Nokia commented that they were happy with the Siemens compromise proposal of –40 dB. The question to be answered would be which of two values, -25 dB or -40 dB, should be used for the IPDL. Document R4-021640 contains the vote proposal by the chairman
R4-021640 IPDL vote document (Chairman)
After off line discussions the interested parties agreed a common proposal so the vote is finally cancelled. The following CRs are the results of this agreement, which proposes a value of -35 dB
Decision: The vote is cancelled
R4-021687 BS IPDL requirement (CR 159r1 to 25.104 Rel-4) (Siemens)
R4-021688 BS IPDL requirement (CR 160r1 to 25.104 Rel-5) (Siemens)
Decision: The CRs are agreed
Dostları ilə paylaş: |