Notify District Testing if rejecting material.
707.44
|
Polyvinyl Chloride Sanitary Pipe
|
If material is shipped with TE24, accept based on inspection of material for type, condition and dimension.
Document in CMS.
If no TE24, accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data.
Document in CMS
|
Notify District Testing if rejecting material.
|
707.45
|
Polyvinyl Chloride Solid Wall Pipe
|
If material is shipped with TE24, accept based on inspection of material for type, condition and dimension.
Document in CMS.
If no TE24, accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data.
Document in CMS
|
Notify District Testing if rejecting material.
|
707.46
|
Polyvinyl Chloride Drain Waste and Vent Pipe
|
If material is shipped with TE24, accept based on inspection of material for type, condition and dimension.
Document in CMS.
If no TE24, accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data.
Document in CMS
|
Notify District Testing if rejecting material.
|
707.47
|
ABS and Polyvinyl Chloride Composite Pipe
|
If material is shipped with TE24, accept based on inspection of material for type, condition and dimension.
Document in CMS.
If no TE24, accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data.
Document in CMS
|
Notify District Testing if rejecting material.
|
707.51
|
ABS Drain Waste and Vent Pipe
|
If material is shipped with TE24, accept based on inspection of material for type, condition and dimension.
Document in CMS.
If no TE24, accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data.
Document in CMS
|
Notify District Testing if rejecting material.
|
707.52
|
ABS Sewer Pipe
|
If material is shipped with TE24, accept based on inspection of material for type, condition and dimension.
Document in CMS.
If no TE24, accept based on inspection of material for type, condition, dimension, receipt and verification of manufacturer’s certified test data.
Document in CMS
|
Notify District Testing if rejecting material.
|
707.70
|
Welded and Seamless Steel Pipe
|
Verify type and brand name of material is on QPL at the time of use.
Document in CMS.
|
Notify District Testing and OMM, structural metals and Welding section, if rejecting material because material non-performs or looks defective during use.
|
708.01
|
Inorganic Zinc Silicate Primer Paint
|
Products will be supplied by a source on the Certified List for S-1084 maintained by OMM.
Verify type and brand name of material is on QPL at the time of use.
Inspect material container for markings, expiration date and condition.
Document in CMS.
|
Notify District Testing and OMM, chemical section, if rejecting material because material non-performs or looks defective during use. Obtain a 1 qt (1 L) sample representative of the defects.
|
708.02
708.02B
708.02C
708.02D
|
OZEU Structural Steel Pant
Organic Zinc Prime Coat
Epoxy Intermediate Coat
Urethane Finish Coat
|
Products will be supplied by a source on the Certified List for S-1084 maintained by OMM.
Verify type and brand name of material is on QPL at the time of use.
Inspect material container for markings, expiration date and condition.
Document in CMS.
|
Notify District Testing and OMM, chemical section, if rejecting material because material non-performs or looks defective during use. Obtain a 1 qt (1 L) sample representative of the defects.
|
709.01
|
Deformed and Plain Billet Steel Bars for Concrete Reinforcement
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples of each rebar size, with markings, and submit for QA testing by the Laboratory.
|
709.03
|
Rail Steel Deformed and Plain Bars for Concrete Reinforcement
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples of each rebar size, with markings, and submit for QA testing by the Laboratory.
|
709.05
|
Axle Steel Deformed and Plain Bars for Concrete Reinforcement
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples of each rebar size, with markings, and submit for QA testing by the Laboratory.
|
709.08
|
Cold-Drawn Steel Wire for Concrete Reinforcement
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples of each diameter and submit for QA testing by the Laboratory.
|
709.09
|
Fabricated Steel Bar or Rod Mats for Concrete Reinforcement
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) of the mat and submit for QA testing by the Laboratory.
|
709.10
|
Welded Steel Wire Fabric for Concrete Reinforcement
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) of the mat and submit for QA testing by the Laboratory.
|
709.11
|
Deformed Steel Wire for Concrete Reinforcement
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) of the mat and submit for QA testing by the Laboratory.
|
709.12
|
Welded Deformed Steel Wire Fabric for Concrete Reinforcement
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) of the mat and submit for QA testing by the Laboratory.
|
709.13
|
Coated Dowel Bars
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain 3 dowel bars and submit for QA testing by the Laboratory.
|
709.14
|
Epoxy-Coated Steel Wire and Welded Wire Fabric for Reinforcement
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain 3 ft x 3 ft (1 m x 1 m) of the mat and submit for QA testing by the Laboratory.
|
709.15
|
Plastic Supports for Reinforcing Steel
|
Products will be supplied by a source on the Approved List maintained by OMM.
Inspect for dimension and condition.
|
Notify District Testing if rejecting material that non-performs or looks defective during use.
|
709.16
|
Galvanizing Steel Option for Bridge Spirals
|
Products will be supplied by a source on the Certified List for S-1068 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain three (3) 30" (.8 m) long samples of each rebar size, with markings, and submit for QA testing by the Laboratory.
|
710.01.A
710.01 B
|
Barbed Wire
|
Products will be supplied by a source on the Certified List for S-1067 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain a 5 ft (1.5 m) length of barbed wire and submit for QA testing by the Laboratory.
|
710.02
|
Woven Steel Wire Fence, Type 47
|
Products will be supplied by a source on the Certified List for S-1067 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain 4 ft (1.2 m) width of fencing and submit for QA testing by the Laboratory.
|
710.03
|
Chain-Link Fence
[ including Fittings and Accessories]
|
Products will be supplied by a source on the Certified List for S-1067 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain samples as directed by the Laboratory.
|
710.06
|
Deep Beam Rail
|
Products will be supplied by a source on the Certified List for S-1042 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain three (3) 1 ft (0.3 m) lengths of guardrail from the same section and submit for QA testing by the Laboratory.
|
710.09
|
Wire Rope Rail
|
Inspect for dimension, condition, appearance and markings on tag or reel.
Submit one (1) six (6) ft. sample to OMM.
Document in CMS.
|
Approval required prior to use. 1Notify District Testing and OMM.
|
710.11
|
Fence Posts and Braces
[Lumber]
[Steel]
|
Products will be supplied by a source on the Certified List for S-1067 and S-1072 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
710.12
|
Square-Sawed and Round Guardrail Posts
|
Products will be supplied by a source on the Certified List for S-1042 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
710.14
|
Pressure Treated Guardrail and Fence Posts, Braces, and Blocks
|
Products will be supplied by a source on the Certified List for S-1042 and S-1067 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
710.15
|
Steel Guardrail Posts
|
Products will be supplied by a source on the Certified List for S-1042 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
710.16
|
Guard Posts
|
Products will be supplied by a source on the Certified List for S-1042 and S-1067 maintained by OMM.
Received with TE-24.
Check dimension, markings and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
711.01
711.04
711.07
|
Structural Steel
Cold Rolled Steel
Steel Castings
|
Material supplied by a Fabricator source on the Certified List for Items 513, 516, 517 & 518 maintained by OMM.
Structural Steel Members are received with TE-24.
|
If questions concerning structural steel materials, contact OMM Structural Steel Section 1and notify District Testing.
|
711.02
|
Galvanized Steel
|
Any material supplied with galvanizing will conform to this specification. Randomly inspect galvanizing for appearance and thickness of coating.
|
Notify District Testing if rejecting material.
|
711.03
|
Steel for Sheet Piling
|
Certified Mill Test Data required for new material.
Verify tensile and chemical properties meet requirements.
Inspect all material for dimension and condition.
Used material is not acceptable for permanent installations.
Document field inspection.
|
|
711.08
|
Arc-welding Electrode & Fluxes
|
Verify manufacturer is on Approved List maintained by OMM.
Inspect for dimension, condition and markings.
Document in CMS.
|
If material is not on Approved List, certification and test data from supplier will be submitted to OMM. Do not use until approval has been received.
|
711.09
|
High Strength Bolts
Nuts and Washers
|
Received with TE-24.
Inspect material for dimension, condition and markings.
Reject defective material.
Perform field testing of assembly combination per S-1080.
Document field inspection & testing in CMS.
|
If field test does not meet requirements of S 1080, retest bolt, nut and washer combination after application of a lubricant.
Notify District Testing if rejecting material.
|
711.10
|
Machine Bolts
|
General specification for many common bolts
Verify material is component of certified supplier shipment like S-1042 for Guardrail Suppliers or S-1067 for Fence Suppliers.
Inspect for condition and coating.
Reject defective material.
|
Notify District Testing if rejecting material.
|
711.12
711.13
711.14
|
Gray Iron Castings
Ductile Iron Castings
Gray Iron & Ductile Iron Castings
|
Verify manufacturer is on Approved List maintained by OMM.
Received with TE-24.
Inspect for condition and defect.
|
1Notify District Testing if rejecting material
|
711.15
711.16
711.17
711.18
711.19
|
Sheet Copper
Phosphor Bronze Plate
Cast Bronze
Leaded Bronze
Sheet Lead
|
Material supplied by a Fabricator source on the Certified List for Items 513, 516, 517 & 518 maintained by OMM.
Structural Steel Members are received with TE-24.
Document in CMS.
|
If questions concerning structural steel materials, contact OMM Structural Steel Section 1and notify District Testing.
|
711.20
|
Aluminum for Railings
|
Material supplied by a Fabricator source on the Certified List for Items 513, 516, 517 & 518 maintained by OMM.
Structural Steel Members are received with TE-24.
Document in CMS.
|
If questions concerning structural steel materials, contact OMM Structural Steel Section 1and notify District Testing.
|
711.21
|
Preformed Bearing Pads
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
If material non-performs or looks defective during use 1notify District Testing and OMM.
|
711.23
|
Elastomeric Bearings
|
Only accept elastomeric bearings shipped by TE-24.and provided by certified suppliers conforming to S1081. Notify district testing. to
Inspect material to check location and number of internal shims utilizing an ice pick or similar tool.
Five (5) Durometer Gage readings should be taken and averaged to determine compliance with design plans.
Document in CMS.
|
Field acceptable for durometer. Reading average range: +/- 7 points of design plan number.
|
711.24
|
Waterproofing fabric
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
|
711.25
|
Type 2 Membrane Waterproofing
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use send one (1) 4 ft2 sample representative of defect to OMM for QA follow-up.
|
711.26
|
Structural Timber, Lumber and Piling
|
Products will be supplied by a source on the Certified List for S-1072 maintained by OMM.
Received with TE-24 and supplier bill of lading.
Check dimension, quantity and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
711.27
|
Prestressing Steel
|
Material supplied by a Fabricator source on the Certified List for Items 515 maintained by OMM.
Prestressed Concrete Members are received with TE-24.
|
If questions concerning prstressed concrete or prestressed
|
711.28
|
Cellular Polyvinyl Chloride Sponge
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use send
one (1) 1.5'x2.5' sample representative of defect to OMM for QA follow-up.
|
711.29
|
Type 3 Membrane Waterproofing
|
Verify type and brand name of material is on QPL at the time of use.
Membrane primer is 705.04 material
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use send
one (1) 4 square ft sample representative of defect to OMM for QA follow-up.
|
711.30
|
Aluminum for Steps
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
711.31
|
Reinforced Propylene Plastic Manhole Steps
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
712.01
|
Expansion Shield Anchors
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain three(3) samples representative of defect to OMM for QA follow-up.
|
712.02
|
Calcium Chloride
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use contact OMM.
|
712.03
|
Sodium Chloride
|
Inspect material for condition.
Submit one (1) pint sample per Each Purchase Order to OMM.
Document in CMS.
|
If additional samples required for material quantities exceeding 3000 tons, Notify District Testing.
|
712.04 A
|
Lime [masonry]
|
Sample & Inspect material for condition with 24 hrs of receipt.
One (1) five (5) lb sample for Masonry and Stabilization purposes.
One (1) ten (10) lb sample of Quicklime. Send to Geotechnical Engineering.
Document in CMS.
|
Notify District Testing if rejecting material.
Samples may be taken in triplicate, if required. Contact Geotechnical Engineering.
|
712.04 B
|
Lime [Quick]
Stabilization
|
Assure provided material is from suppliers certified under Supplement 1087 and documentation for m S1087 is complete. Document in CMS.
If questions on material quality Ssample.
One (1) five (5) lb sample for Masonry and Stabilization purposes.
One (1) ten (10) lb sample of Quicklime. Send to Geotechnical Engineering..
|
Notify District Testing if rejecting material.
Samples may be taken in triplicate, if required. Contact Geotechnical Engineering.
|
712.04 B
|
Lime [Hydrated] Stabilization
|
Assure provided material is from suppliers certified under Supplement 1087 and documentation for m S1087 is complete. Document in CMS.
If questions on material quality sample.
One (1) five (5) lb sample for Masonry and Stabilization purposes.
One (1) ten (10) lb sample of Quicklime. Send to Geotechnical Engineering
|
Notify District Testing if rejecting material.
Samples may be taken in triplicate, if required. Contact Geotechnical Engineering.
|
712.04 C
|
Lime [Hydrated] Stabilization
|
Assure provided material is from suppliers certified under Supplement 1087 and documentation for m S1087 is complete. Document in CMS.
If questions on material quality sample.
One (1) five (5) lb sample for Masonry and Stabilization purposes.
One (1) ten (10) lb sample of Quicklime. Send to Geotechnical Engineering
|
Notify District Testing if rejecting material.
Samples may be taken in triplicate, if required. Contact Geotechnical Engineering.
|
712.06
|
Preservative Treatment for Structural Timber
|
Component material of pressure treated lumber. No approval required.
|
If questions on pressure treated lumber check the specific material item and follow those instructions
|
712.09
|
Geotextile Fabrics
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use submit one (1) 4' x 4' sample representative of defect to OMM.
|
712.10
|
Prefabricated Edge Underdrain
|
Inspect material for condition and dimension.
Manufacturer’s certified test data required for acceptance.
Document in CMS.
|
Notify District Testing if rejecting material.
|
712.11
|
Temporary Erosion Control Mats Material
[Types A through I]
|
Inspect material for condition and dimension.
Manufacturer’s certified test data required for acceptance.
Field Acceptance item
Refer to Temporary Materials Policy for documentation requirements.
|
Notify District Testing if rejecting material.
|
720.01
|
Rectangular Reflectors
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, color requirements and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
720.03
|
Flexible Delineator Posts
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
720.04
|
Barrier Reflectors
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
721.01
|
Raised Pavement Marker Castings
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify type conforms to pre-qualification requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain one (1) 4x2x0.48 in. sample representative of defect to OMM for QA follow-up.
|
721.02
|
Prismatic Retroreflector
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify type conforms to pre-qualification requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use. Obtain one (1) sample representative of defective RPM casting to OMM for QA follow-up.
|
721.03
|
Casting Adhesive
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
721.04
|
Prismatic Retroreflector Adhesive
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition and defect.
Verify dimension conform to plan requirements.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use
|
725.02
|
Electrical Cables
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use send a sample representative of non -compliance or defect to OMM for QA follow-up.
|
725.03
|
Unit Type Duct-Cable Systems
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use send a 10 ft. sample representative of non -compliance or defect to OMM for QA follow-up.
|
725.04
|
Rigid Ferrous Metal Electrical Conduit and Fittings
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition of coating and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use send a sample representative of non -compliance or defect to OMM for QA follow-up.
|
725.051
|
Polyvinyl Chloride Conduit and Fittings
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use send a sample representative of non -compliance or defect to OMM for QA follow-up.
|
725.052
|
Polyethylene Conduit and Fittings
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use send a sample representative of non -compliance or defect to OMM for QA follow-up.
|
725.06
|
Polymer Concrete Pull Boxes
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use send a sample representative of non -compliance or defect to OMM for QA follow-up.
|
725.07
|
Plastic Pull Box
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use 1notify District Testing and OMM.
|
725.08
|
Portland Concrete Pull Boxes
|
Products will be supplied by a source on the Certified List for S-1073 maintained by OMM.
Received with TE-24.
Check dimension, markings, roughness or excessive cracks.
Item 604 Installation documented on CA-P-3 Inspection Form.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM..
|
725.10
|
Junction Boxes
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.11 B
|
Lamps for Luminaires
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.11 E
|
Luminaires for High Intensity Discharge Lamps (including Optical system, lamp, ballast and housing)
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.11 F
|
Wall Mounted Underpass Luminaires (including Optical system, lamp, ballast and housing)
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.11 G
|
High Mast/Low Mast Luminaire (including Optical system, lamp, ballast and housing)
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.12
|
Polyethylene, Fiberglas reinforced, Pull Box with Polymer concrete cover and support ring
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.15
|
Circuit Cable Connections and terminations
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.16
|
Ground Rods
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use contact OMM.
|
725.19 I
|
Power Service Components
Wood Pole
|
Products will be supplied by a source on the Certified List for S-1072 maintained by OMM.
Received with TE-24 and supplier bill of lading.
Check dimension, quantity and condition.
Document in CMS.
|
Notify District Testing and OMM, structural welding and metals section, if rejecting material because material non-performs or looks defective during use.
|
725.20
|
Multiple Cell Polyvinyl Chloride Conduit and Fittings
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, markings and conformance to plan requirements.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.21 A
|
Luminaire Supports
Light Poles
|
Inspect material for condition and conformance to plan requirements.
Verify pole provided by Certified Manufacturer under Supplement 1091.
Accept with TE-24
Document in CMS
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.21 B
|
Luminaire Supports
Light Towers
|
Inspect material for condition and conformance to plan requirements.
Verify pole provided by Certified Manufacturer under Supplement 1091.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
725.21B9
|
Luminaire Support
Anchor Bolts
|
OPTION 1
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, and conformance to plan requirements.
OPTION 2
Verify pole provided by Certified Manufacturer under Supplement 1091.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.01
|
Steel Tube and Pipe
|
This item typically is a component of a sign support. Inspect total component for condition and conformance to shop drawings.
Document in CMS
|
Notify District Testing if rejecting material.
|
730.015
|
U-Channel Posts
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District testing and OMM.
|
730.016
|
Square Posts
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.02
|
Steel Anchor Bolts and Nuts
|
OPTION 1
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, and conformance to plan requirements.
OPTION 2
Verify pole provided by Certified Manufacturer under Supplement 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.03
|
Steel Poles and Arms
|
Component material provided by Certified Manufacturer under Supplement 1093.
Verify manufacturer is on 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.04
|
Base and Arm Plates
|
Component material provided by Certified Manufacturer under Supplement 1093.
Verify manufacturer is on 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.05
|
Handhole Covers
|
Component material provided by Certified Manufacturer under Supplement 1093.
Verify manufacturer is on 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.06
|
Pole Caps
|
Component material provided by Certified Manufacturer under Supplement 1093.
Verify manufacturer is on 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.07
|
Arm Caps
|
Component material provided by Certified Manufacturer under Supplement 1093.
Verify manufacturer is on 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.08
|
Steel Hardware
|
Component material provided by Certified Manufacturer under Supplement 1092 or 1093.
Verify manufacturer is on 1092 or 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.09
|
Stainless Steel
|
Component material provided by Certified Manufacturer under Supplement 1092 or 1093.
Verify manufacturer is on 1092 or 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.10
|
Stainless Steel Hardware
|
Component material provided by Certified Manufacturer under Supplement 1092 or 1093.
Verify manufacturer is on 1092 or 1093
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.11
|
Aluminum Sheet and Plate
|
Component material provided by Certified Manufacturer under Supplement 1092 or 1093.
Verify manufacturer is on 1092 or 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.12
|
Aluminum Extrusions
|
Component material provided by Certified Manufacturer under Supplement 1092 or 1093.
Verify manufacturer is on 1092 or 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.13
|
Aluminum Tube and Pipe
|
Component material provided by Certified Manufacturer under Supplement 1092 or 1093.
Verify manufacturer is on 1092 or 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.14
|
Aluminum Castings
|
Component material provided by Certified Manufacturer under Supplement 1092 or 1093.
Verify manufacturer is on 1092 or 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.15
|
Aluminum Forgings
|
Component material provided by Certified Manufacturer under Supplement 1092 or 1093.
Verify manufacturer is on 1092 or 1093.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.16
|
Aluminum Welding Rods
|
Normally only applies to shop fabrication. If performing field aluminum welding contact District Testing and OMM for recommendations.
|
Notify District Testing if rejecting material.
|
730.17
|
Aluminum Hardware
|
Component material provided by Certified Manufacturer under Supplement 1092.
Verify manufacturer is on 1092.
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.18
|
Reflective Sheeting Type F
|
Use if certification provided.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM..
|
730.19
|
Reflective Sheeting Type G
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.191
|
Reflective Sheeting Type G rebondable
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.192
|
Reflective Sheeting Type H
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.193
|
Reflective Sheeting Type J
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.20
|
Nonreflective Sheeting
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
730.22
|
Silk Screen Inks
|
No field acceptance requirements.- part of 730.19,191,192 or 193 items.
|
|
730.23
|
Transparent Electronic Cuttable Films
|
No field acceptance requirements.- part of 730.19,191,192 or 193 items No field requirements.
|
|
731.01
|
Mercury Vapor Luminaire
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
731.03
|
Changeable Message Sign, Electrical Type
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
731.05
|
Internally Illuminated Fixed Message Sign
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
731.06
|
Sign Flasher Assembly
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
731.07
|
School Speed Limit Sign Assembly
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
731.08
|
Flexible Conduit
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
731.10
|
Timer with Enclosure
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.01
|
Vehicular Signal Heads, Conventional
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.02
|
Vehicular Signal Heads, Optically Programmed, 12-inch (300 mm) Lens
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.03
|
Vehicular Signal Heads, Optically Programmed, 8-inch (200 mm) Lens
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.04 A
|
Optically Programmed
And Pedestrian Incandescent Signal Lamps
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.04 B
|
Vehicular Signal Incandescent Lamps
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.04 C
|
Vehicular and pedestrian light Emitting Diode Lamps
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.05
|
Pedestrian Signal Heads
[Type A1]
[Type A2]
[Type D2]
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.06
|
Pedestrian Pushbuttons
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.07 A
|
Loop Detector Units Nema TS 1
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.07 B
|
Loop Detector Units Nema TS 2
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.08
|
Loop Detector Units, Delay and Extension Type
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.09
|
Magnetometer Detector Units
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.10
|
Magnetometer Sensor Probes
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.11
|
Signal Supports
|
Check provided by Certified Manufacturer under Supplement 1094
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.12
|
Strain Poles
|
Check provided by Certified Manufacturer under Supplement 1094
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.13
|
Wood Poles
|
Check provided by Certified Manufacturer under Supplement 1072
Accept with TE-24.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.14
|
Down Guy Assemblies
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.15
|
Pedestals
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.16
|
Conduit Risers
|
See 725.04 requirements.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.17
|
Cable Support Assemblies
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.18
|
Messenger Wire
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.19
|
Cable and Wire
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.20
|
Power Service
|
See 725.04 requirements
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
732.21
|
Disconnect Switch with Enclosure
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.02 A
|
Controller Unit Type TS2/A1
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.02 B
|
Controller Unit Type TS2/A2
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.02 C
|
Controller Unit Type 170E
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.02 D
|
Controller Unit Type 2070L and LC
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.03 A
|
Cabinet Type TS 1
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.03 B
|
Cabinet Type TS 2
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.03 C
|
Cabinet Type 332
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.03 D
|
Cabinet Type 334
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.03 E
|
Cabinet Type 336
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.04 A
|
Cabinet Riser for TS 1 – TS 2 cabinet
|
Field inspect for 1/4 aluminum thickness and accept.
|
Notify District Testing if rejecting material.
|
733.04 B
|
Cabinet Riser for Types 332, 334 or 336
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.05
|
Flasher Controller
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for conformance to dimension and condition.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
733.06
|
Controller, Master, Traffic Responsive
|
Assure the same manufacturer as the supplied controller unit 733.02.
|
Notify District Testing if rejecting material.
|
733.07
|
Remote Monitoring Station
|
Compatible with the supplied 733.02 and 733.06 unit.
|
Notify District Testing if rejecting material.
|
740.02
|
Traffic Paint
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District.
|
740.03
|
Polyester Pavement Marking
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District.
|
740.04
|
Thermoplastic Pavement Marking
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District.
|
740.05
|
Preformed Pavement Marking
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District.
|
740.06
|
Work Zone Pavement Marking
[Type 1 Removable]
[Type 2 Non-Removable]
|
Materials accepted by Engineer.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District.
|
740.07
|
Epoxy Pavement Marking Material
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District
|
740.08
|
Heat-Fused Preformed Plastic Pavement Marking Material
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District
|
740.09 A
|
Glass Beads – for 740.02
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District.
|
740.09 B
|
Glass Beads – for 740.03
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District.
|
740.09 C
|
Glass Beads – for 740.04
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District.
|
740.09 D
|
Glass Beads – for 740.07
|
Verify material is on Approved List maintained by OMM.
Accepted with TE-24.
Inspect container for appropriate markings.
Inspect material for uniform consistency.
Document in CMS.
|
If rejecting for performance provide 1 qt (1 L) sample and notify District.
|
748.01
|
Ductile Iron Pipe, Joints, and Fittings
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.02
|
Polyvinyl Chloride (PVC) Pipe, Joints, and Fittings
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.03
|
Polyethylene (PE) Service Branches and Fittings
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.05
|
Copper Service Branches and Fittings
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.06
|
Steel Pipe Encasement
|
Basis of acceptance is certified test data containing documentation of domestic origin from manufacturer.
|
Notify District Testing if rejecting material
|
748.07
|
Polyethylene Encasement
|
Verify manufacturer certification conforms to ANSI/AWWA C105/A21.5
Inspect condition, dimension, suitability for intended use.
|
Notify District Testing if rejecting material.
|
748.08
|
Gate Valve and Valve Box
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.09
|
Inserting Valve and Valve Box
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.10
|
Cutting-in Sleeve, Valve, and Valve Box
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.11
|
Tapping Sleeve, Valve, and Valve Box
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.12
|
Tapping Saddle and Corporation Stop
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.13
|
Service Stop and Service Box
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|
748.14
|
Meter, Setting, Stop, and Chamber
|
Inspect for condition, dimension, suitability for intended use.
Acceptance based on manufacturer’s statement of conformity.
|
|
748.15
|
Fire Hydrant
|
Verify type and brand name of material is on QPL at the time of use.
Inspect for condition, dimension, suitability for intended use.
Document in CMS.
|
Notify District Testing if rejecting material.
If material non-performs or looks defective during use notify District Testing and OMM.
|